Manual, F/T Sensor, Ethernet Axia
Document #9620-05-C-Ethernet Axia-02
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
C-86
13.3
Ethernet Axia Webpage Errors
Symptom: The Invalid Request
page appears.
Cause:
One or more entries on the previous webpage were invalid
or out of range.
Solution:
Go back to the previous page and review the last entry. To
make debugging easier, make only one change at a time.
Symptom:
The HTTP
1.0 401 Error -
Unauthorized
page appears
Cause:
The user tried to access one of the protected pages of the web server.
Solution:
These pages are reserved for ATI Industrial
Automation maintenance.
13.4 Java
®
Demo Errors
Symptom: Demo displays
zeros for force
and torque values
and displays
question marks for
configuration data.
Cause:
The Demo program is not able to communicate with the sensor.
Solution:
Check IP address and restart demo.
Symptom: Excessive IO
exception: Receive
timed out errors
Cause:
The Ethernet connection was interrupted.
Solution:
Verify the Ethernet cabling is not damaged and properly
installed. Verify the power supply meets the requirements
listed in
.
Symptom:
Error message: IO
exception: <path
and file name>
(The process
cannot access
the file because it
is being used by
another process)
Cause:
Selected file for data is in use by another program.
Solution:
Close file or change file name and select Collect
Streaming again.
Symptom:
The following
message appears
in a window titled
Java
®
Virtual
Machine Launcher:
“Could not find
the main class.
Program will exit.”
Cause:
Computer requires a newer version of Java
®
.
Solution:
Download a newer version of Java
®