Manual, F/T Sensor, Ethernet Axia
Document #9620-05-C-Ethernet Axia-02
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
C-80
11.2
Calibration Information (netftcalapi.xml)
The XML page netftcalapi.xml retrieves information about a specific calibration. Retrieved calibration
information has not been modified by any of the Ethernet Axia configuration settings.
A calibration index can be specified when requesting this calibration information. This is done by appending
?index=n
to the request, where n is the index of the desired calibration. If a calibration index is not specified
the currently-used calibration will be assumed.
For example, to retrieve calibration information for the second calibration the requested page would be
netftcalapi.xml?index=1
.
Table 11.3—XML Elements in netftcalapi.xml
XML Element
Data Type
Calibration Information
calsn
STRING8
Serial number
calpn
STRING32
Calibration type
caldt
STRING20
Calibration date
calmtx
REAL
Matrix value
calfu
USINT
Force units (refer to config.cgi variable cfgfu for values)
scalfu
STRING8
Name of force units
caltu
USINT
Torque units used (refer to config.cgi variable cfgtu for
values)
scaltu
STRING8
Name of torque units
calmr
REAL[6]
Calibrated sensing ranges in calfu and caltu units
calcpf
DINT
Counts per force unit
calcpt
DINT
Counts per torque unit
calrng
REAL
Calibrated sensing range