Manual, F/T Sensor, Ethernet Axia
Document #9620-05-C-Ethernet Axia-02
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
C-58
Table 8.1—Commands
Command
Operand(s)
Description
SAVEALL
Not Applicable
This command records all values that
remain through a power cycle to NVM.
STATUS
Not Applicable
If there could be an underlying problem
within the sensor hardware, the “status”
command can be used to retrieve
detailed information or for a user to send
the information to ATI for troubleshooting.
The “status” command reports various
components of the sensor. The content of
this command varies among sensors.
VIEW
no operand
The “view” command reports properties
such as the F/T part number, units,
calibration date, and calibration family.
If a user sends this command without an
operand, all calibrations are reported.
0
Calibration 0
1
Calibration 1
A
Active calibration
DIAG
Not Applicable
The diagnostic status command provides
a report for each of the gages within the
sensor. Compare this information to the
values in the applicable sensor manual;
refer to
. Use the “status”
command, for troubleshooting.
The report includes the following: gage
number, gage readings in counts, gage
status indicator, F/T axis, F/T reading in
units, all-time peak data, and the active
tool transformation.
8.3 Console “CAL” | “SET” Command Fields and Values
The “set” command reports all settings. Note that “CAL” is synonymous for “set”, but in this manual, the
command is referenced to as “set”. Many settings are read-only fields that are configured onto the sensor
during ATI factory calibration. All setting fields are listed in
.
“set” command format, for example:
user:
set
response:
Field
Value
-----
-----
serialNum
FT22835
partNum
SI-150-8
calFamily
Ethernet
...