5 - MAINTENANCE
5-29
ANNUALLY
Check Accumulator
1. Unfold the machine into the
Field Position
Till Folding & Unfolding” on page 4-11)
2. Lower the disks to the ground by retracting the
Front
Wheel Cylinders
A
and
Rear Roller Cylinders B
.
A
B
Fig. # 5-40 Lower Disks to the Ground
3. Relieve all the hydraulic pressure by placing the tractor
SCV levers to the
FLOAT POSITION
with engine
running for the
Main Frame Lift
&
Wing Fold
cylinders.
4. The machine should now be in the
“Field Lowered Po-
sition”
WARNING
Only qualified and trained personnel should perform this
procedure. Always wear personal protective equipment.
WARNING
HIGH PRESSURE VESSEL
Avoid injury from high pressure escaping
hydraulic fluid.
• Relieve pressure from hydraulic system before
servicing
• Precharge with dry nitrogen gas only.
Failure to comply could result in serious injury or
death.
5. The accumulator pressure should be checked annually.
6. Operational dry nitrogen pressure levels are between
700-800 psi (4826-5516 kPa) (48.3-55.2 bar). If levels
are below this range, recharge the accumulator with dry
nitrogen.
7. If pressure is 0 psi (0 kPa) (0 bar), replace the accumulator
due to an internal bladder rupture.
WARNING
Always use dry inert gas (Dry Nitrogen - N2) for pre-
charging.
NEVER USE AIR OR OXYGEN, DUE TO THE DANGER
OF COMBUSTION / EXPLOSION
A
Fig. # 5-41 Nitrogen Check Port Location
Summary of Contents for Kwik-Till HSD2500
Page 2: ......
Page 10: ...1 4 1 GENERAL INFORMATION This Page Is Intentionally Left Blank...
Page 91: ...4 WORKING OPERATIONS 4 25 Fig 4 69 3 Rear Roller Deflector Locations A A...
Page 92: ...4 WORKING OPERATIONS 4 26 This Page Is Intentionally Left Blank...
Page 134: ...5 MAINTENANCE 5 42 This Page Is Intentionally Left Blank...
Page 144: ...8 FORMS AND DECLARATIONS 8 2 This Page Is Intentionally Left Blank...
Page 152: ...i 6...
Page 153: ......