Network Video Recorder
User Manual
UI System Setting
86
Issue: V4.6.X(2022-04-24)
Parameter
Description
Setting
Alarm Output
Mode
When the device receives I/O alarm
signals, it will send the alarm
information to an external alarm device
in the mode specified by this parameter.
The options include the switch mode
and pulse mode.
NOTE
⚫
If the switch mode is used, the alarm
frequency of the device must be the
same as that of the external alarm
device.
⚫
If the pulse mode is used, the alarm
frequency of the external alarm
device can be configured.
[Setting method]
Select a value from the
drop-down list box.
[Default value]
Switch Mode
Alarm Time(ms)
(0: Continuous)
Alarm output duration. The value
0
indicates that the alarm remains
continuous valid.
[Setting method]
Enter a value manually.
[Default value]
0
[Value range]
0 to 86400 seconds
Manual Control
Control the alarm output.
N/A
----End
7.4
Network Management
Set the
Network Parameter, 802.1X, DDNS, E-mail, Port Mapping, P2P, IP Filter, SNMP,
Network Traffic
in the network management screen.
Operation Description
Step 1
Click
Network
in the main menu (or click the network page of any function screen in the
main menu) to access the network management screen, as shown in Figure 7-36.