North&Wing&S,LSA&Maintenance&Manual&
Model:&Sport&X2&582&
Issue 3.2
Printed: July 16 2017
Page 86
Turn on the ignition switch. Turn the FULL and EMPTY adjustment
screws located on top of unit to the full CW (clockwise) position.
Setting The “Empty “ Point
Setting the “Empty” m
ust be done with the probe out of the tank
or when tank is empty.
Slowly turn the EMPTY screw CCW (counter clockwise) until the
needle on the meter just stops moving downward. The needle
should be on or just below the empty mark. Now turn the screw CW
(clockwise) to make sure the needle starts moving upscale
immediately, then turn CCW until the needle just stops moving
downward again. This is the EMPTY reference mark. Repeat this
step until you are sure the EMPTY reference is obtained.
Setting The “Full” Point
Put the probe into your tank. Turn the FULL screw CCW until the
needle indicates the liquid level in your tank. For best results, the
probe should be fully immersed in a full tank. If you accidentally
adjust below your tank level, turn the FULL screw full cw and repeat
this setting.
Remove the unit from the tank. Shake the unit a few times to
remove the residual liquid. The needle should now rest on or below
the empty mark. This completes the calibration. Do not make any
more adjustments.