43
S
ECTION
15
Message
Descrip
Ɵ
on
Cause
Solu
Ɵ
on
SITE INTERFERENCE CHANGE
RADIO CHANNEL
Controller is recognizing units
in the system that are causing
radio interference.
There is a local signal nearby
opera ng on the same radio
channel.
Change the radio channel, or
assign a CUSTOM PASSCODE
to create a unique network.
Navigate to the FAULT LOGS
MENU and CLEAR the mes-
sage.
PROBLEM DETECTED ON
LAMP: X REPAIR MACHINE
Current overload (short
circuit) or underload (open
circuit) lamp outputs
Faulty wire connec on
Faulty wires
Faulty lamp
Faulty controller
Check connec ons and recon-
nect wiring
Check wires, replace where
necessary
Replace faulty lamp
Replace faulty controller
ATTENTION: SEE PRIMARY
UNIT
Secondary sees a problem
with the Primary unit
Problem with Primary signal
Go to Primary signal to view
error
ATTENTION: SEE SECONDARY
UNIT “x”
Primary sees a problem with
Secondary unit “x”
Problem with Secondary “x”
signal
Go to Secondary “x” signal to
view error
DEFAULT FLASH RED
Default
fl
ashing, as shown on
Secondary machine
Previous fault has cleared
automa cally
Machine Failure
Press “START” bu on on
Primary when ready to start
program
See Primary unit for instruc-
on
DEFAULT FLASH RED PRESS
START TO RESUME
Default
fl
ashing, as shown on
Primary machine
Previous fault has cleared
automa cally
Machine Failure
Press “START” bu on on
Primary when ready to start
program
See Primary unit for instruc-
on
ALL STOP
System is in “all red”,
Secondary unit
All stop has been triggered by
radio remote or “ALL STOP”
bu on on the Primary or Sec-
ondary controller
Press “START” bu on on
Primary, when ready to start
program
Press “RESUME PROGRAM” at
the Secondary unit at which
the ALL STOP was conducted
ALL STOP PRESS START TO
RESUME
System is in a red state at all
units
All stop has been triggered by
preemp on, radio remote or
“ALL STOP” bu on on con-
troller
Press “START” bu on on
Primary, when ready to start
program
STARTED OPERATING FINE
Normal opera on, as shown
on Primary machine
Signal is opera ng within
normal parameters
OPERATING FINE
Normal opera on, as shown
on Secondary machine
Signal is opera ng within
normal parameters