BATTERY LOW CHARGE FOR
48 HRS
Ba ery bank voltage is read-
ing low
Ba ery charge is below 23.6V,
machine will s ll operate
Plug internal charger into
110V power source for min-
imum 24hrs of con nuous
charging
MALFUNCTION RESPONSE
BATTERY DEAD CHARGE FOR
48 HRS
Malfunc on management sys-
tem detected that the ba ery
is too low to operate
Ba ery charge is below 23.0V,
machine will not operate
Plug internal charger into
110V power source for min-
imum 48hrs of con nuous
charging
MACHINE FAULT CHECK RS-
485 WIRING
Communica ons meout on
the RS-485 network
Wiring harness to controller
faulty
Malfunc on management
system link is broken
Controller failure
Replace faulty harness
Check unit diagnos c tab,
check for Malfunc on man-
agement system link (checked
box)
Replace controller
CHANGING…
Machines are changing states
(between default
fl
ashing,
default all stop, opera ng)
MALFUNCTION RESPONSE
NO LAMPS (DARK) REPAIR
MACHINE
Malfunc on management sys-
tem detected that no lamps
were displayed
All LED lamps not connected
Faulty controller
Connect LED lamps
Replace controller
MALFUNCTION RESPONSE
CHECK LAMP WIRING
REPAIR MACHINE
Malfunc on management
system detected a ming fault
on a lamp circuit
LED lamp(s) not connected
Faulty controller
Connect LED lamp(s)
Replace controller
MALFUNCTION RESPONSE
CONFLICTING LAMPS
REPAIR MACHINE
Malfunc on management
system detected a con
fl
ic ng
lamp output
Short circuit in wiring
LED lamps connected to
wrong terminal
Check and replace faulty
wiring
Check wiring diagram and
terminal block
DEFAULT ALL RED PRESS
START TO RESUME
Default solid red, as shown on
Primary machine
Previous fault has cleared
automa cally
Press “START” bu on on
Primary, when ready to start
program
DEFAULT ALL RED
Default solid red, as shown on
Secondary machine
Previous fault has cleared
automa cally
Press “START” bu on on
Primary, when ready to start
program
HOLD FOR RAILROAD
While running automa c
cycle, system has paused for
railroad preemp on (all red)
Signals are opera ng within
normal parameters
Automa c cycle will restart
once the system is told the
railroad is clear
DEFAULT FLASHER PRESS
START TO RESUME
When primary unit is
fi
rst
powered
Post-power up
Press START PROGRAM