Installation / 31
P0881594 Issue 01
MICS-XC Norstar-Companion Installer Guide
Installing Base Stations
Before installing wireless equipment, ensure that a site planner
has determined Base Station locations and recorded them in
the Provisioning Record.
41
OBIX14
BS14
-PWR
Yellow-Blue
16
Blue-Yellow
42
TCM
Yellow-Orange
17
Orange-Yellow
43
+PWR
Yellow-Green
18
Green-Yellow
44
OBIX15
BS15
-PWR
Yellow-Brown
19
Brown-Yellow
45
TCM
Yellow-Slate
20
Slate-Yellow
46
+PWR
Violet-Blue
21
Blue-Violet
47
OBIX16
BS16
-PWR
Violet-Orange
22
Orange-Violet
48
TCM
Violet-Green
23
Green-Violet
49
+PWR
Violet-Brown
24
Brown-Violet
50
25
Each Base Station must be installed within 1230 m
(4000 ft., TCM wiring length) of the ICS or Base
Station Module.
To optimize seamless hand-off, the difference in TCM
wiring length between neighboring Base Stations
should not exceed 300 m (1,000 ft.).
Pin
RPI Connector Board
Label
Wire color
p0881594.book Page 31 Tuesday, August 25, 1998 3:59 PM
Summary of Contents for Companion MICS-XC
Page 2: ......
Page 12: ...6 Norstar Companion basics MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Page 50: ...44 Installation MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Page 52: ...46 Powering up the system MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Page 137: ......