September 2007
Test and Debug Capabilities
Planning, Installation, and Administration Guide
55
If the internal RAM test, ALU test, address mode test, boot ROM test, timer
test, or external RAM test fails, the pack goes into a maintenance loop
because no further processing is possible.
If a test fails, F:XX shows on the HEX display for three seconds after the
T:13 message, with the number represented by XX indicating the test that
failed. For example, if the 8051 co-processor test failed, F:05 shows. If more
than one test fails, the message indicates the first failure.
T:11
Testing host dual port RAM
T:12
Testing DS-30 dual port RAM
T:13
Testing SEEPROM
T:14
Booting IXP1200, waiting for response with selftest
information
T:15
Not used at present
T:16
Not used at present
T:17
Not used at present
T:18
Not used at present
T:19
Not used at present
T:20
Waiting for application start-up message from IXP1200
T:21
T:21 CardLAN enabled, waiting for request configuration
message
T:22
T:22 CardLAN operational, A07 enabled, display now
under host control
VPOK
Card booted but slot not enabled at switch
CRC
Card fully booted and operational
Code
Code description
Summary of Contents for Call Recording
Page 2: ......
Page 12: ...Getting Started Standard 1 0 12 Nortel Call Recording Card ...
Page 46: ...Configuring the Nortel Call Recording Card Standard 1 0 46 Nortel Call Recording Card ...
Page 62: ...Test and Debug Capabilities Standard 1 0 62 Nortel Call Recording Card ...
Page 90: ...Standard 1 0 90 Nortel Call Recording Card ...
Page 91: ...Planning Installation and Administration Guide 91 A p p e n d i x B Glossary ...
Page 93: ......