Chapter 8 Installing an expansion unit
N0027152 01
N0027152 01
To set GASM dip switches
1
For the dip switches on the left side, at the rear of the module, set all the switches to on.
2
For the dip switches on the right side, at the rear of the module, set the switches according to
Table 17
and
Table 18
.
3
After you have set the switches, proceed to
“Installing a media bay module in an expansion
unit” on page 95
.
To set GATM dip switches
1
For the dip switches on the left side, at the rear of the module, set all the switches to on.
2
For the dip switches on the right side, at the rear of the module (country profile switches), set
all of the switches to off. The GATM downloads the country profiles automatically.
3
After you have set the switches, proceed to
“Installing a media bay module in an expansion
unit” on page 95
.
Table 17 GASM dip switch settings (switch 1–3)
Switch
Description
Setting
Switch 1
Firmware download capability
OFF — Standard mode (firmware downloading not
supported)
ON — Enhanced mode (firmware downloading supported)
Switch 2
Set when the firmware is
downloaded from the BCM50
(for enhanced mode only)
OFF — if you want the GASM to download the firmware
when the firmware version in the BCM50 is different than the
version in the GASM (default)
ON — if you want the GASM to download the firmware
whenever there is a cold start of the BCM50
Switch 3
Enable/disable echo
cancellation
OFF — Enables echo cancellation (default)
ON — Disables echo cancellation
Table 18 GASM dip switch settings (switch 4–8)
Switches 4 to 8 select the region for the GASM as follows:
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
North America
OFF
OFF
OFF
OFF
OFF
United Kingdom
OFF
OFF
OFF
OFF
ON
Australia
OFF
OFF
OFF
ON
OFF
Poland
OFF
OFF
OFF
ON
ON
Summary of Contents for BCM50
Page 1: ...Part No N0027152 01 08 April 2005 BCM50 Installation and Maintenance Guide ...
Page 8: ...8 Task List N0027152 01 N0027152 01 ...
Page 16: ...16 Contents N0027152 01 N0027152 01 ...
Page 34: ...34 Chapter 1 Getting started with BCM50 N0027152 01 N0027152 01 ...
Page 58: ...58 Chapter 2 Introducing the BCM50 hardware N0027152 01 N0027152 01 ...
Page 70: ...70 Chapter 4 Determining DHCP server configuration and IP address N0027152 01 N0027152 01 ...
Page 74: ...74 Chapter 5 Installing the BCM50 system N0027152 01 N0027152 01 ...
Page 96: ...96 Chapter 8 Installing an expansion unit N0027152 01 N0027152 01 ...
Page 116: ...116 Chapter 10 Installing telephones and peripherals N0027152 01 N0027152 01 ...
Page 122: ...122 Chapter 11 Installing the analog terminal adapter N0027152 01 N0027152 01 ...
Page 126: ...126 Chapter 12 Configuring the BCM50 system N0027152 01 N0027152 01 ...
Page 148: ...148 Chapter 15 Using the Startup Profile to configure parameters N0027152 01 N0027152 01 ...
Page 158: ...158 Chapter 17 Connecting the BCM50 system to the LAN and WAN N0027152 01 N0027152 01 ...
Page 168: ...168 Chapter 19 Replacing the BCM50 system components N0027152 01 N0027152 01 ...
Page 172: ...172 Chapter 20 Replacing a power supply N0027152 01 N0027152 01 ...
Page 178: ...178 Chapter 21 Replacing a main unit N0027152 01 N0027152 01 ...
Page 182: ...182 Chapter 22 Replacing a media bay module N0027152 01 N0027152 01 ...
Page 214: ...214 Appendix E DTM wiring chart N0027152 01 N0027152 01 ...
Page 220: ...220 Appendix G GATM wiring chart N0027152 01 N0027152 01 ...
Page 224: ...224 Appendix H 4x16 wiring charts N0027152 01 N0027152 01 ...
Page 240: ...240 Appendix K System region attributes N0027152 01 N0027152 01 ...
Page 246: ...246 Index N0027152 01 N0027152 01 ...