Appendix K System region attributes
237
BCM50 Installation and Maintenance Guide
Digital trunk types
Table 60
provides a description of the types of digital trunk types.
Note that some of these line types are available only when specific regions are chosen.
Table 60 Digital trunk types and descriptions (Sheet 1 of 2)
Digital trunk
types
Description
T1/E1
Digital line that carries data on 24 channels at 1.544 Mbps (North American); 30 channels
at 2,048 Mbps (Europe)
Loop, E&M, DID and ground start lines are also versions of T1 lines.
You can program auto-answer T1 loop start, T1 E&M trunks, T1 DID, T1 ground start
trunks, PRI and IP trunks to map to target lines to provide for attendant bypass (calling
directly to a department or individual) and line concentration (one trunk can map onto
several target lines).
DID
This is a type of T1 trunk line that allows an outside caller to dial directly into a line on the
BCM50.
Loop
This is a type of T1 line. This type of line is used on systems where the service provider
supports disconnect supervision for the digital loop start trunks.
These trunks provide remote access to the Business Communications Manager from the
public network. This trunk must have disconnect supervision to allow the trunk to be set to
auto-answer, which provides the remote access portal.
Ground
T1-groundstart trunk
These lines offer the same features as loop start trunks, but are used when the local
service provider does not support disconnect supervision for digital loop start trunks.
Ground start trunks work with T1 only. By configuring lines as ground start, the system
recognizes when a call is released at the far end.
E&M
T1 and E&M. This type of trunk line is used to create simple network connections to other
phone systems.
This trunk always operates in a disconnected supervised mode.
PRI
ISDN interface with 23 B channels and 1 D channel at 1.544 Mbps (in Europe: 30
B-channels and 1 D-channels at 2.048 Mbps).
These lines give you incoming and outgoing access to an ISDN network and are
auto-answer trunks.
BRI
ISDN loop that provides both T and S reference point loops.
These loops can support both network (T and S loops) and terminal equipment (S loop)
connections.
This type of line provides incoming and outgoing access to an ISDN network. ETSI ISDN
BRI is the European Telecommunications Standards Institute specification for BRI ISDN
service. BRI provides two bearer B-channels operating at 64 kbits/s and a data D-channel
which operates at 16 kbits/s. The D-channel is used primarily to carry call information. Like
loop start trunks, BRI lines can be configured as manual-answer or auto-answer.
DASS2
(British) Trunk provides multi-line IDA interconnection to the British Telecom network.
Summary of Contents for BCM50
Page 1: ...Part No N0027152 01 08 April 2005 BCM50 Installation and Maintenance Guide ...
Page 8: ...8 Task List N0027152 01 N0027152 01 ...
Page 16: ...16 Contents N0027152 01 N0027152 01 ...
Page 34: ...34 Chapter 1 Getting started with BCM50 N0027152 01 N0027152 01 ...
Page 58: ...58 Chapter 2 Introducing the BCM50 hardware N0027152 01 N0027152 01 ...
Page 70: ...70 Chapter 4 Determining DHCP server configuration and IP address N0027152 01 N0027152 01 ...
Page 74: ...74 Chapter 5 Installing the BCM50 system N0027152 01 N0027152 01 ...
Page 96: ...96 Chapter 8 Installing an expansion unit N0027152 01 N0027152 01 ...
Page 116: ...116 Chapter 10 Installing telephones and peripherals N0027152 01 N0027152 01 ...
Page 122: ...122 Chapter 11 Installing the analog terminal adapter N0027152 01 N0027152 01 ...
Page 126: ...126 Chapter 12 Configuring the BCM50 system N0027152 01 N0027152 01 ...
Page 148: ...148 Chapter 15 Using the Startup Profile to configure parameters N0027152 01 N0027152 01 ...
Page 158: ...158 Chapter 17 Connecting the BCM50 system to the LAN and WAN N0027152 01 N0027152 01 ...
Page 168: ...168 Chapter 19 Replacing the BCM50 system components N0027152 01 N0027152 01 ...
Page 172: ...172 Chapter 20 Replacing a power supply N0027152 01 N0027152 01 ...
Page 178: ...178 Chapter 21 Replacing a main unit N0027152 01 N0027152 01 ...
Page 182: ...182 Chapter 22 Replacing a media bay module N0027152 01 N0027152 01 ...
Page 214: ...214 Appendix E DTM wiring chart N0027152 01 N0027152 01 ...
Page 220: ...220 Appendix G GATM wiring chart N0027152 01 N0027152 01 ...
Page 224: ...224 Appendix H 4x16 wiring charts N0027152 01 N0027152 01 ...
Page 240: ...240 Appendix K System region attributes N0027152 01 N0027152 01 ...
Page 246: ...246 Index N0027152 01 N0027152 01 ...