![Nortel BCM50 Installation And Maintenance Manual Download Page 164](http://html.mh-extra.com/html/nortel/bcm50/bcm50_installation-and-maintenance-manual_1706243164.webp)
164
Chapter 18 Testing basic BCM50 functionality
N0027152 01
N0027152 01
Reset levels
Reset to factory settings is a stand-alone feature that has the following levels of reset:
•
Level 1 reset erases all customer specific data and restores the default configuration for all
components. It leaves the software components untouched. That is, the system has the latest
release and patch level of the software installed on the system. Only the system and user
configuration data is erased and replaced with default values. There is no Ethernet
connectivity to the system during this operation.
•
Level 2 reset erases all customer and system configuration data and all software releases and
patches. It re-installs the configuration that the system had when it was shipped from factory.
Level 2 reset also resets the router firmware to what was shipped from the factory. There is no
Ethernet connectivity to the system during this operation.
Activate the reset feature
You activate the reset feature by pressing the reset switch with a long, thin, non-metallic needle in
the sequence described in the procedure
“To perform a Level 1 and Level 2 reset”
.
As you press the reset switch, the LEDs blink in a pre-defined fashion to guide and confirm user
input. The various states of the power and status LEDs indicate the following:
•
A blinking power LED indicates a “user input window” – the BCM50 system is waiting for
user input.
•
A solid red power LED indicates “extreme action has been requested – caution urged”.
•
A solid status LED (any color) indicates level of reset action:
— Level 1 is yellow
— Level 2 is red
•
A blinking status LED indicates “interim state – trying to establish user request”.
•
A solid status LED indicates confirmation of user selection (power LED has priority).
To perform a Level 1 and Level 2 reset
The router configuration of a BCM50a or BCM50e is not affected by a Level 1 reset. To reset the
router configuration, use Element Manager to perform a soft reset on the router.
Refer to
Figure 62 on page 165
or follow the sequence in
Table 32 on page 166
and
Table 33 on
page 166
to perform a Level 1 and Level 2 reset.
Caution:
Only use this feature in situations where all customer-specific data
must be erased.
Summary of Contents for BCM50
Page 1: ...Part No N0027152 01 08 April 2005 BCM50 Installation and Maintenance Guide ...
Page 8: ...8 Task List N0027152 01 N0027152 01 ...
Page 16: ...16 Contents N0027152 01 N0027152 01 ...
Page 34: ...34 Chapter 1 Getting started with BCM50 N0027152 01 N0027152 01 ...
Page 58: ...58 Chapter 2 Introducing the BCM50 hardware N0027152 01 N0027152 01 ...
Page 70: ...70 Chapter 4 Determining DHCP server configuration and IP address N0027152 01 N0027152 01 ...
Page 74: ...74 Chapter 5 Installing the BCM50 system N0027152 01 N0027152 01 ...
Page 96: ...96 Chapter 8 Installing an expansion unit N0027152 01 N0027152 01 ...
Page 116: ...116 Chapter 10 Installing telephones and peripherals N0027152 01 N0027152 01 ...
Page 122: ...122 Chapter 11 Installing the analog terminal adapter N0027152 01 N0027152 01 ...
Page 126: ...126 Chapter 12 Configuring the BCM50 system N0027152 01 N0027152 01 ...
Page 148: ...148 Chapter 15 Using the Startup Profile to configure parameters N0027152 01 N0027152 01 ...
Page 158: ...158 Chapter 17 Connecting the BCM50 system to the LAN and WAN N0027152 01 N0027152 01 ...
Page 168: ...168 Chapter 19 Replacing the BCM50 system components N0027152 01 N0027152 01 ...
Page 172: ...172 Chapter 20 Replacing a power supply N0027152 01 N0027152 01 ...
Page 178: ...178 Chapter 21 Replacing a main unit N0027152 01 N0027152 01 ...
Page 182: ...182 Chapter 22 Replacing a media bay module N0027152 01 N0027152 01 ...
Page 214: ...214 Appendix E DTM wiring chart N0027152 01 N0027152 01 ...
Page 220: ...220 Appendix G GATM wiring chart N0027152 01 N0027152 01 ...
Page 224: ...224 Appendix H 4x16 wiring charts N0027152 01 N0027152 01 ...
Page 240: ...240 Appendix K System region attributes N0027152 01 N0027152 01 ...
Page 246: ...246 Index N0027152 01 N0027152 01 ...