![Nortel BCM50 Installation And Maintenance Manual Download Page 134](http://html.mh-extra.com/html/nortel/bcm50/bcm50_installation-and-maintenance-manual_1706243134.webp)
134
Chapter 14 Using Element Manager to set the basic parameters
N0027152 01
N0027152 01
Accessing the BCM50
system
Use the following procedures to access the BCM50 system through the OAM port.
To download and install Element Manager
1
Connect one end of the Ethernet cable to the OAM port on the main unit, and connect the other
end to the Ethernet port on your computer.
The DHCP-enabled computer is assigned IP address 10.10.11.2. (255.255.255.252).
2
Open a web browser and enter the IP address 10.10.11.1 (BCM50 OAM port IP address).
The Enter Network Password dialog box opens.
3
Enter the following username and password:
Username: nnadmin
Password: PlsChgMe!
4
Click Ok.
The Welcome to BCM50 web page opens.
5
From the Welcome to BCM50 web page, click Administrator Applications.
The Administrator Applications page opens.
6
From the Administrator Applications page, click BCM50 Element Manager.
The Element Manager panel opens.
7
Click Download Element Manager on the right side of the screen.
8
When BCM50 Element Manager has finished downloading, double-click the application and
follow the instructions to install.
To connect to the BCM50 system
1
Open Element Manager.
2
From the Network menu, select New Network Element, then select Business
Communications Manager.
3
Enter the IP address, 10.10.11.1 in the dialog box.
4
Click Ok.
5
Select the address 10.10.11.1 from the Network Elements folder.
6
Enter the following username and password:
Username: nnadmin
Password: PlsChgMe!
7
Click Connect.
You are now connected to the BCM50 system.
Summary of Contents for BCM50
Page 1: ...Part No N0027152 01 08 April 2005 BCM50 Installation and Maintenance Guide ...
Page 8: ...8 Task List N0027152 01 N0027152 01 ...
Page 16: ...16 Contents N0027152 01 N0027152 01 ...
Page 34: ...34 Chapter 1 Getting started with BCM50 N0027152 01 N0027152 01 ...
Page 58: ...58 Chapter 2 Introducing the BCM50 hardware N0027152 01 N0027152 01 ...
Page 70: ...70 Chapter 4 Determining DHCP server configuration and IP address N0027152 01 N0027152 01 ...
Page 74: ...74 Chapter 5 Installing the BCM50 system N0027152 01 N0027152 01 ...
Page 96: ...96 Chapter 8 Installing an expansion unit N0027152 01 N0027152 01 ...
Page 116: ...116 Chapter 10 Installing telephones and peripherals N0027152 01 N0027152 01 ...
Page 122: ...122 Chapter 11 Installing the analog terminal adapter N0027152 01 N0027152 01 ...
Page 126: ...126 Chapter 12 Configuring the BCM50 system N0027152 01 N0027152 01 ...
Page 148: ...148 Chapter 15 Using the Startup Profile to configure parameters N0027152 01 N0027152 01 ...
Page 158: ...158 Chapter 17 Connecting the BCM50 system to the LAN and WAN N0027152 01 N0027152 01 ...
Page 168: ...168 Chapter 19 Replacing the BCM50 system components N0027152 01 N0027152 01 ...
Page 172: ...172 Chapter 20 Replacing a power supply N0027152 01 N0027152 01 ...
Page 178: ...178 Chapter 21 Replacing a main unit N0027152 01 N0027152 01 ...
Page 182: ...182 Chapter 22 Replacing a media bay module N0027152 01 N0027152 01 ...
Page 214: ...214 Appendix E DTM wiring chart N0027152 01 N0027152 01 ...
Page 220: ...220 Appendix G GATM wiring chart N0027152 01 N0027152 01 ...
Page 224: ...224 Appendix H 4x16 wiring charts N0027152 01 N0027152 01 ...
Page 240: ...240 Appendix K System region attributes N0027152 01 N0027152 01 ...
Page 246: ...246 Index N0027152 01 N0027152 01 ...