Repair
6-3
Part 107016-02
E
2016 Nordson Corporation
4. Remove the gun mount and the hose bracket (3) or diffuser (5) from the
old multiplier/resistor assembly (6). Save the screws (4, 7) for reuse.
5. Install the gun mount and the hose bracket or diffuser on the new
multiplier with the screws removed from the old multiplier.
6. Install the powder path parts.
7. Install the spray gun on the mounting bar. Tighten the gun mount set
screws (1) securely.
8. Connect the gun cable, feed hose, and air tubing (if it is used) to the
spray gun.
1400419B
2
1
3
4
5
6
7
1
Figure 6-2
Multiplier Replacement
1. Set screws
2. Gun mount
3. Hose bracket
4. Screw
5. Diffuser
6. Multiplier/resistor assembly
7. Screws