Troubleshooting
5-5
Part 107016-02
E
2016 Nordson Corporation
Resistor Resistance Check
See Figure 5-3.
1. Perform steps 1 through 3 under
Multiplier/Resistor Assembly Continuity
and Resistance Check
.
2. Unscrew the resistor probe (2) from the multiplier (4).
3. Connect the megohmmeter probes to the electrode (1) and
resistor spring (3). The megohmmeter should read between
153 and 187 megohms at 500 volts. If the reading is out of this range,
replace the resistor probe.
1400420B
1
2
3
4
5
6
Figure 5-3
Resistor Resistance Check
1. Electrode
2. Resistor probe
3. Resistor spring
4. Multiplier
5. Multiplier well
6. Resistor probe cavity