Description
A 2-13
Part 331235C
E
2003 Nordson Corporation
Part A: System Overview
Specifications
Specifications are subject to change without notice.
Electrical
Main input voltage
85
−
240 Vac, 50/60 Hz
1
, 10 amp (300 VA)
Gun output
6
−
21 Vdc
Maximum current
600 mA
Maximum short circuit current
50 mA
ANSI/ISA-S82.01
Pollution Degree 1
Overvoltage Category III
Pneumatic
Operating Air Pressures
Minimum input air pressure
5.6 bar (80 psi)
Maximum input air pressure
7 bar (100 psi)
Typical Air Pressures
Flow rate air
2 bar (30 psi)
Atomizing air
1 bar (15 psi)
Gun air
0.6 bar (10 psi) fixed
Air Supply Quality
Main input air must be clean and dry. Use a regenerative desiccant or
refrigerated air dryer capable of producing a 3.4
_
C (38
_
F) or lower
dewpoint at 7 bar (100 psi). Install a filter system with prefilters and
coalescent type filters capable of removing oil, water, and dirt in the
submicron range.
Summary of Contents for Sure Coat
Page 6: ...Table of Contents ii Part 331235C E 2003 Nordson Corporation Part A System Overview...
Page 14: ...Safety A 1 4 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Page 34: ...Installation A 3 6 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Page 52: ...Operation A 5 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Page 64: ...Troubleshooting A 6 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...