Troubleshooting
A 6-3
Part 331235C
E
2003 Nordson Corporation
Part A: System Overview
1400389A
Figure A 6-2
Diagnostic Mode Display
NOTE:
Pressing the Nordson key during the diagnostics sequence
aborts the sequence.
a. An error code or dashes are shown on the digital display. Dashes
indicate that no error or alarm condition is present.
b. If error codes are displayed, dashes are shown when there are no
more error codes.
c. The total spray timer value is displayed as HRSx10, and the
number 1 is displayed in the upper left corner.
d. The service timer value is displayed as HRSx10, and the number 2
is displayed in the upper left corner.
e. All segments and icons light on the LCD display.
f. The controller type is displayed (for example, SC3).
g. The software version is displayed (for example, 3.0).
h. Dashes are displayed to signify that the internal checks are
completed.
NOTE:
After the entire diagnostics procedure is completed, the controller
automatically exits the diagnostics mode and reverts to the previously set
operating mode.
3. Record all error codes.
NOTE:
Make sure to record error codes before turning off power. Error
codes are erased when power is turned off.
4. If an error code is available, refer to
Error Codes
to locate the error and
perform the corrective action.
5. If an error code was not recorded, re-enter the diagnostics mode to view
and record the error code.
Summary of Contents for Sure Coat
Page 6: ...Table of Contents ii Part 331235C E 2003 Nordson Corporation Part A System Overview...
Page 14: ...Safety A 1 4 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Page 34: ...Installation A 3 6 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Page 52: ...Operation A 5 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...
Page 64: ...Troubleshooting A 6 12 Part 331235C E 2003 Nordson Corporation Part A System Overview...