Operation
4-23
Part 1611362
−
01
E
2018 Nordson Corporation
Shutdown
1. Move the system offline, if applicable.
2. Clean the system by performing the color change process, but do not
install a new powder source or turn
On
the pumps, sieve, or vibratory
table.
3. If the powder feed center will be shut down for maintenance, repair, or
an extended period of time, perform the following steps:
a. Press the
Stop
button on the system control panel.
b. Turn the electrical disconnect switch on the powder feed center
control panel to the
Off
position.