Appendix A, Command Function Reference
(continued)
Step & Repeat Y
Click
Function
Works exactly like Step & Repeat X except that priority is given to the Y axis instead of to the X axis, as shown
below.
Step & Repeat, X Axis Direction
Step & Repeat, Y Axis Direction
Difference between Step & Repeat X and Step & Repeat Y
Step & Repeat Z
Click
Function
Double-click
address and
select from
drop-down
menu
Enables the repeat of the dispensing pattern onto many identical workpieces that are mounted on a fixture plate
and aligned in rows and columns.
Parameter
Description
Z Offset
The distance (in mm) between each workpiece tier in the Z direction.
• A positive Z Offset value moves the tip away from the work surface.
• A negative Z Offset value moves the tip towards the work surface.
Range: 0.1–100 (mm)
Tier
The number of tiers (or levels) in the Z direction.
Range: 1–9999
Label
The address where the Step & Repeat Z command begins.
Y Offset (in mm)
Tier
Z Offset
(in mm)
Diagram of the Z Offset and Tier Parameters