36
Applicators
P/N 317091G
E
2011 Nordson Corporation
EP11 / EP 12
Problem
Possible Cause
Corrective Action
Refer to
No material
Melter tank is empty
Fill
Separate manual
Melter
Melter motor and/or pump is
not switched on
Switch on
Melter pump is not working
Check
Separate manual for
pump or melter
Applicator has not yet
reached operating
temperature
Wait until temperature has
been reached; adjust
temperature setting if
necessary
Separate manual
Temperature
controller
Applicator cold or not warm
enough
Refer to
Applicator does not
heat
- -
Control air not connected
Connect
Page
Nozzle clogged
Clean nozzle
Page
Nozzle stem is stuck
Replace control module(s)
Separate manual for
control module
Filter cartridge or nozzle
filter clogged
Clean
Page
Page
Applicator does
not heat
Temperature not set
Adjust
Page
Voltage plug not connected
Connect
Page
Fuses in melter defective
Disconnect unit from line
voltage, check fuses and
replace if necessary
- -
Heater cartridge(s) in
applicator defective
Replace heater cartridge(s)
- -
Applicator does
not reach the set
temperature
One or more heater
cartridges defective
Replace
- -
Ambient temperature too
low
Increase ambient
temperature
- -
Solenoid valves
do not switch
Control unit not switched on
Switch on
Separate manual
Control Unit
Valve connecting cable not
plugged in or loose
Check that plug connections
are tight
Page
Continued...