10
Applicators
P/N 317091G
E
2011 Nordson Corporation
EP11 / EP 12
Installing
When installing the applicator, the following points should be observed in
order to avoid unnecessary effort later.
S
Protect from humidity, vibrations, dust and drafts
S
Ensure access to parts relevant for maintenance and operation
S
Install/attach the applicator to/in the parent machine with the mounting
bracket. To achieve optimum material application, during assembly
ensure that the distance and, when appropriate, the angle between the
nozzle and the substrate can be varied.
S
When installing the unit, ensure that cables, air hoses, and heated hoses
can not be bent, pinched, torn off or otherwise damaged.
Exhausting Material Vapors
Ensure that material vapors do not exceed the prescribed limits. Exhaust
material vapors when necessary. Provide sufficient ventilation of the location
where the unit is installed.
Electrical Connection
WARNING:
Risk of electrical shock. Failure to observe may result in
personal injury, death, or equipment damage.
Laying Cable
WARNING:
Ensure that cables do not touch rotating and/or hot unit
components. Do not pinch cables and check regularly for damage. Replace
damaged cables immediately!
Electrically Connecting Applicator
The unit is connected electrically by inserting the plugs into the
corresponding receptacles of the melter or a terminal box. Secure the voltage
plug with the clamp if necessary.
Connecting Solenoid Valves
The solenoid valves on the control modules are controlled either by an
external power supply, e.g. control unit, or through the valve control lines of
the heated hose. Secure the voltage plug with the clamp if necessary.
NOTE:
Observe the voltage stated on the ID plate of the solenoid valve.