Applicators
15
P/N 317091G
E
2011 Nordson Corporation
EP11 / EP 12
Setting Control Air Pressure
The control air pressure is set to suit each application on an air conditioning
unit. The air conditioning unit with pressure control valve is not part of the
applicator.
NOTE:
It is important to observe the instructions on lubricating or not
lubricating the control air (page
) and in the separate manuals for the
control modules!
Set control air pressure:
5 to 6 bar
0.5 to 0.6 MPa
72.5 to 87 psi
The exact pressure must be determined for each application.
NOTE:
The maximum control air pressure may not be exceeded.
Nordson will assume no warranty or liability for damage resulting from
incorrect pressure settings.
Setting Material Pressure
The material pressure is generated by the melter pumps.
CAUTION:
The maximum material pressure may not be exceeded:
70 bar
7 MPa
1015 psi