© 2022 Nordson Corporation
4-2
Error Codes and Alarm Messages
Table 4-1 Error Codes and Messages
Code
Message Text
Description
Refer to
Page
NA = Not currently applicable
* - Code may differ on early software releases
10x
CAN and Node State
101
CAN bus fault detected
N/A
102
CAN receive buffer overflow
Host CAN interface receive too much data and could not
process it quickly enough
103
Message timeout
Remote CAN device did not respond to a direct response in
the allotted time.
104
Went offline
Remote CAN device is no longer online
105
Returned to online
Remote CAN device returned to service
106
Communication error
Host CAN interface detected a communication error
107
BUS−OFF
255 bad CAN messages received
108
Warning Limit exceeded
127 bad CAN messages received
109
Bit error
Dominant bit not detected in 5 data bits
110
Form error
Fixed format data field contains illegal bits
111
Stuffing error
Recessive bit not detected in 5 data bits
112
Other error
Other errors not listed as Bit, Stuff, or Form
113
CAN Transmit Buffer
overflow
Host CAN interface did not transmit data quickly enough
20x
Application
201
Conveyor input not detected Not implemented, future release
202
Encoder not detected
Not implemented, future release
203
Zone photoeye stuck on
Not implemented, future release
204
Flag photoeye stuck on
Not implemented, future release
205
Application setup
Not implemented, future release
206
System in lockout
Not implemented, future release
30x
Electrostatic Controller (Spray Gun Card)
301
Micro-Amp fault detected
Micro-amp value out of range.
302
Over-current fault detected
Over-current detection.
303
Feedback fault detected
No micro-amp feedback detected.
304
Open circuit detected
No multiplier load detected.
305
Short circuit detected
Multiplier drive circuit shorted.
306
Internal hardware fault
detected
Internal DSP fault.
308
Spray gun not detected
Spray gun not connected to system.
Continued...
Summary of Contents for Encore HD iControl 2
Page 6: ...2022 Nordson Corporation 1609758 04 iv Table of Contents...
Page 8: ...2022 Nordson Corporation 1609758 04 ii Change Record...
Page 84: ...2022 Nordson Corporation 1609758 04 4 34 Troubleshooting...
Page 102: ...2022 Nordson Corporation 1609758 04 6 12 Parts...
Page 104: ...2022 Nordson Corporation 1609758 04 7 2 Drawings...
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 113: ......
Page 114: ......