Installation
3-7
E
1996 Nordson Corporation
All rights reserved
108 390B
Issued 7/96
Manual 10-10
Mount the atomizing air regulator outside the cabinet if it is too large to fit
inside. See Figure 3-3 and follow these steps:
1. Connect a grounded air hose (6) to the
1
/
4
-in. NPT x
1
/
4
-in. NPSM
fitting (2) on the flow sensor (3). Route the hose through the fluid
outlet hole in the cabinet to the regulator inlet.
2. Connect another grounded air hose (6) between the regulator outlet
and spray device air inlet.
3. Connect a ground strap or wire (5) between the
1
/
4
in. NPT x
1
/
4
in.
NPSM hose fitting (2) and the cabinet air inlet fitting.
WARNING:
Risk of electrical shock. Failure to connect a
ground strap may result in personal injury, death, or equipment
damage. Check for continuity between the spray device handle
and the ground.
Installing Regulator Outside
Cabinet
Summary of Contents for Compact Manual Iso-Flo Voltage-Block
Page 5: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1 Section 1 Safety...
Page 6: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Page 20: ...Safety 1 14 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Page 42: ...Operation 4 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 50: ...Operation 4 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 58: ...Repair 6 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 62: ...Parts 7 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...