7. Put the spring (6) on the cartridge stem.
8. Invert the body (4) and push the valve cartridge (8) through the hole.
Put an alignment mark on the body and the top.
9. Put the large ball in first. The lever goes down, with the small ball on
top.
10. Put the body on the top, aligning with the marks.
11. Holding firmly, invert the flow sensor and replace the screws (11).
12. Remove the plugs.
13. Reinstall the flow sensor into the cabinet and reconnect all lines.
1010038A
2
3
5
4
6
8
9
10
11
12
1
7
Cutaway view of flow sensor
1. Main air input
2. Screen
3. Ball
4. Body
5. Atomizing air output
6. Spring
7. Pressure switch output
8. Valve cartridge
9. Lever
10. O-ring
11. Socket-head cap screw
12. Flow sensor cap
3. Flow Sensor Repair
(contd.)
Summary of Contents for Compact Manual Iso-Flo Voltage-Block
Page 5: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1 Section 1 Safety...
Page 6: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Page 20: ...Safety 1 14 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Page 42: ...Operation 4 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 50: ...Operation 4 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 58: ...Repair 6 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 62: ...Parts 7 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...