Description
2-4
E
1996 Nordson Corporation
All rights reserved
108 390B
Issued 7/96
Manual 10-10
Table 2-1 Iso-Flo System Components And Their Functions
Component
Function
ÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁ
1. Air regulator and gauge
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Regulates and indicates pilot air pressure to the fluid pressure regulator. The
pressure setting determines the fluid pressure to the spray device.
2. Flow sensor
Supplies and senses the flow of atomizing air to the spray device. Provides a
pilot air signal to operate the shuttle.
NOTE:
The extra port in the housing for the air signal to close the pressure
switch is optional. The customer-supplied pressure switch is wired to actuate
the electrostatic power supply.
3. Drain cock
Simulates atomizing air flow for testing the spray device nozzle flow rate, when
opened.
4. One-way check valve
Prevents two-way air from flowing through the line.
5. Lubricator and sight glass
Mixes lubricant with working air to the pump. Lubricant prevents the pump
seals from wearing prematurely and keeps the pump working smoothly.
6. Iso-Flo pump
Supplies coating material to the spray device. Single-stage, air-operated, 1:1
fluid-to-air ratio.
7. Fluid outlet
Connects the fluid hose to the spray device using a
3
/
8
-in. NPSM male
connector.
8. Air-piloted fluid pressure
regulator
Regulates the fluid pressure to the spray device. Controlled by an air
regulator.
9. Shuttle assembly
Makes or breaks the fluid connection to the spray device in response to a
signal from the flow sensor. The shuttle’s pneumatic cylinder moves the
female coupling and block up and down.
10. Filter bowl
Removes lubricant from the pump exhaust air.
11. Quick exhaust valve
Routes the working air from the lubricator into the pump on an air signal from
the shuttle valve. Routes exhaust air from the pump into the filter.
12. Toggle valve
Puts high air pressure on the pump air motor.
13. Female coupling
Connects to the male coupling when the shuttle is closed to transfer coating
material to pump.
14. Male coupling
Connects to the female coupling when the shuttle is closed to transfer coating
material to the pump.
15. Door interlock valve
Prevents electrical shock. When the door is opened, this valve exhausts pilot
air to the pilot valve, which closes the shuttle and grounds the fluid path.
16. Shuttle valve
Connects the pilot valve to two separate and distinct operating signals.
17. Fluid inlet
Connects to the coating material supply using a
3
/
8
-in. NPT (F) connector.
18. Pilot valve
Controls the air flow to the shuttle in response to a signal from the flow sensor
or door interlock valve.
19. Air inlet
Supplies compressed air using
1
/
4
-in. NPT (F) connector.
20. Ground strap (not illustrated)
and clamp
Connects air inlet to ground. Clamp must be secured to a true earth ground.
Components
(contd.)
Summary of Contents for Compact Manual Iso-Flo Voltage-Block
Page 5: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1 Section 1 Safety...
Page 6: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Page 20: ...Safety 1 14 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Page 42: ...Operation 4 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 50: ...Operation 4 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 58: ...Repair 6 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 62: ...Parts 7 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...