Installation
3-4
E
1996 Nordson Corporation
All rights reserved
108 390B
Issued 7/96
Manual 10-10
1010031A
35 in.
(889 mm)
31 in.
(787 mm)
28 in.
(711 mm)
17.5 in.
(445 mm)
19 in.
(483 mm)
31.5 in.
(800 mm)
1.50 in.
(38 mm)
4
3
5
6
1
2
8
7
11
10
9
Compact Manual Iso-Flo system mounting dimensions and connection points
1. Fluid inlet:
3
/
8
-in. NPTF fitting
2. Compressed air:
1
/
4
-in. NPTF fitting
3. Atomizing air:
1
/
4
-in. NPSM fitting
4. Fluid outlet:
3
/
8
-in. NPSM fitting
5. Electrostatic cable
connection: #10-32 screw
6. Flow sensor port (used with the
pressure switch):
1
/
8
-in. NPTF port
7. Electrostatic cable access
8. Fluid inlet
9. Fluid and atomizing air outlet
10. Ground strap
11. Compressed air line (system air)
2. Mounting and
Connections
(contd.)
Summary of Contents for Compact Manual Iso-Flo Voltage-Block
Page 5: ...E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1 Section 1 Safety...
Page 6: ...Safety 1 0 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Page 20: ...Safety 1 14 E 1995 Nordson Corporation All rights reserved Issued 11 95 A1EN 03 SF LIQD 1...
Page 42: ...Operation 4 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 50: ...Operation 4 8 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 58: ...Repair 6 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...
Page 62: ...Parts 7 0 E 1996 Nordson Corporation All rights reserved 108 390B Issued 7 96 Manual 10 10...