PROPlus / PRO Series Automated Dispensing Systems
149
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
#
Click
Step
Reference Image
3
• Enter the following information for NEEDLE
PROFILE:
- Dispenser number (in this example,
Needle 1 for Dispenser 1)
- Port that the dispenser is connected to
(in this example, Dispense Port 12 for
Dispenser 1)
4
• Use the jog keys to position the tip over the
crosshair target (on either the tip detector or
the one you created).
• Jog the tip down until it as close to the
crosshair target as possible without touching
the target.
5
• Click SET next to Needle Move.
This sets the XYZ coordinates for the
dispense calibration point. The system
enters the dispensing tip coordinates in the
fields under Needle Move and Set.
6
• Jog the camera until the camera crosshairs
are centered over the crosshair target,
then
focus the camera until the image of the
crosshair target is clear.
7
• Click SET next to Camera Move.
This sets the camera position. The system
enters the camera coordinates in the fields
under Camera Move and Set.
8
• Click SAVE.
The system populates the Needle 1 data
fields.
Continued on next page
Appendix E, Multi-Needle Setup and Use (continued)
To Set the Camera-to-Tip Offsets for Multiple Dispensers (continued)