PROPlus / PRO Series Automated Dispensing Systems
130
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Rectangle Adjust
Click
Function
Double-click
address and
select from
drop-down
menu
Used only in a Step & Repeat program and in tandem with the Camera Trigger and Trig Mark commands to
cause the system to adjust the program (from one workpiece to another) for any XY orientation changes in
workpiece placement.
NOTES:
• Use the Camera Trigger, Trig Mark, and Rectangle Adjust commands only in a Step & Repeat program (for
dispensing onto an array).
this command.
• When Camera Trigger, Trig Mark, and Rectangle Adjust are used, the Step & Repeat parameter for path must
be set to S Path.
Set
Click
Function
Double-click
address and
select from drop-
down menu
Allows a numeric value to be assigned to a symbol or character; once assigned, the symbol or character can
be used in a program in place of the numeric value. A set command can also be used to cause the system
to increase or decrease a coordinate by the assigned numeric value.
NOTE:
Unlike the Var command (included later in this section), Set cannot be used with a Find Mark or
Fiducial Mark command.
Parameter
Description
Symbol
Enter the symbol or character that will represent the assigned Value
Value
Enter the numeric value that the symbol or character represents
Example of a program that includes a Set command
Setup Dispense Port
Click
Function
Double-click
address and
select from
drop-down
menu
Allows you to turn on multiple output ports at the same time. For example, to turn on ports 1, 2, and 3, enter
“1.2.3” (with periods between the port numbers, no spaces). The default setting is port 0.
Appendix A, Command Function Reference
(continued)