High-Level Driver FB19
FB19 serves to write a complete line/a channel to configuration data. Configuration messages are sequentially
generated and transmitted via FB20 and FB15/FB16 to the PICO controller.
The line number is adapted to a value code. With value codes 10–16, the line number 100 is automatically used.
INPUT:
• Command, channel, line (each as BYTE)
• Dosing time/Pulse time as REAL
• Pause time as REAL
• Number of runs/Cycle Count as REAL
• IN/Activation as REAL
• Connecting line/Linkage as REAL
• Connecting time/Delay as REAL
• Block number/Block count as REAL
• Dosing Value as REAL
• Ext. puls as REAL
• Container as REAL
• Limit as REAL
• Adjustable range as REAL
• Temperature as REAL
• Stop as REAL
• Delay-Time as REAL
OUTPUT:
• Command as BYTE (for FB20)
• Channel as BYTE (for FB20)
• Line as BYTE (for FB20)
• CodeValue as INT (for FB20)
IN_OUT:
• Start flag as BOOL (for externally triggering writing is lines)
• Value as REAL (sending value)
• Trigger_KD (connected with the FB20 trigger configuration data via DB15, serves as a trigger for sending and as a
send confirmation for a configuration message)