Value
Code
[Decimal]
Line/
Channel
Value Code
Parameter Designation
Value Range
Byte Type
Explanation
PICO
Controller
Display
TXT File
1
Line
Pulse Time
dosing time
0/0.05–9999.99 ms
Float/4/2
2
Line
—
pause time
50000.0 for “v”=variable;
0/0.12–9999.99 ms
Float/4/2
3
Line
Cycl.Count
number of
runs
0–999
Integer/2/—
4
Line
Activation
IN
0–10
Integer/2/—
5
Line
Linkage
connected
line
0–99
Integer/2/—
6
Line
Delay
connecting
time
0–9999.99 ms
Float/4/2
7
Line
Block Count
block number 1–999
Integer/2/—
8
Line
DosingValue
dosing value
0–9999.99 mg
Float/4/2
9
Line
Ext.Puls
ext.puls
0 or 1
Integer/2/—
10
Channel
Container
container
0–9999.99 g
Float/4/2
11
Channel
Limit
limit
0–9999.99 g
Float/4/2
12
Channel
—
adjustable
range
0–100% 1000%=”v”=full
adjustable range
Integer/2/—
13
Channel
Temperature
temperature
0–100 °C or
0–200 °C
Float/4/1
Converts the temperature
adjustment range and
analog output with the
PICO controller for
0–200 °C
14
Channel
Stop
stop
0–2
Integer/2/—
15
Channel
—
Delay-Time
0–9999.99 ms
Float/4/2
10 bit resolution of the
analog input; 0V: pause
time=0.12 ms; 10V:
pause time=Delay-Time
16
Channel
Remaining
—
0–9999.99 g
Float/4/2
21
Line
Pulse Time
dosing time
0/0.05–9999.99 ms
Float/4/2
Cycle remains constant;
pause time adapts as
with a change made to
the PICO controller via
the menu.
22
Line
Cycle
—
(Pulse Time +
0.00 ms/0.12 ms)–
9999.99 ms
Float/4/2
Pulse Time remains
constant; pause time
adapts with a change
directly to the PICO
Controller via the menu
Value Codes and Admissible Value Ranges
PICO Controller 2+2-XCH-V3
27
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.