Super Claws Model LS-2
TROUBLESHOOTING
MAR/2006 (4945-3500)
Section 6-13
PROBLEM
POSSIBLE
CAUSE
SOLUTION
Claw returns to down
position after pulling
spike.
Puller is set for
$
RAIL
#
work.
Put switch in TIE position.
Claws stay up after
pulling a spike.
Puller is set for
$
TIE
#
work.
Put switch in RAIL position.
Puller is set for
$
TIE
#
work.
Put switch in RAIL position.
Claw Open Valve not shifting.
Check valve spool for free
motion and that solenoid is
being energized. Replace valve
if necessary.
Claws will not open
when CLAWS OPEN
button is pushed.
Faulty hand controller.
Replace hand controller.
Claw Open Valve not shifting.
Check valve spool for free
motion and that solenoid is
being energized. Replace valve
if necessary.
Claws do not open
when UP limit switch is
tripped.
Timing Module Faulty.
Replace timing module.
Claw Close valve not shifting.
Check valve spool for free
motion and that solenoid is
being energized. Replace valve
if necessary.
Claws will not close
Faulty hand controller
Replace hand controller.