MAINTENANCE
Super Claws Model LS-2
Section 5-6
MAR/2006 (4945-3500)
D6. Check Air Cleaner Indicators (if equipped)
Do not allow air inlet restriction to exceed 20 inches of
water (5.0 kPa) under any operating conditions. Inspect the
entire air system for leaks daily. Look for torn air inlet piping
or boots and loose or damaged clamps. Have worn or
damaged parts repaired or replaced, as required.
Retighten any loose connections.
D7. Drain Water Separator/Fuel Water Trap on Engine (if equipped)
If the engine is equipped with a fuel/water separator, drain
off any water that has accumulated. Water in fuel can
seriously affect engine performance and may cause water
damage.
D10. Check Hydraulic Oil Level
Inspect the oil level on a daily basis (or
every 10 hours
of
operation) by reading the sight gauge located on the side of
the reservoir. At full level, the oil should be to the top of the
sight gauge. The hydraulic system uses SAE-20 (ISO 46)
oil. Before filling the system with hydraulic oil, be sure that
the fluid is as specified and that it is clean. Do not use cloth
strainers or fluid that has been stored in contaminated
containers.
Care should be taken to keep the hydraulic oil free of dust,
water, sealing compounds and other foreign matter. While
using the sight gauge, verify oil quality. If oil becomes dark
or milky colored, it should be changed immediately.
NOTE: Always add hydraulic oil to reservoir through a filter.
NEVER OVERFILL RESERVOIR. Never use
hydraulic brake fluid in lieu of hydraulic oil.
D11. Check Hydraulic Oil Filter Indicators
To keep the hydraulic system clean and free from moisture,
there is a return line filter and a strainer in the hydraulic
system.
The hydraulic oil filters have indicator lights on the center
console to provide a visual display of filter cleanliness.
Units are equipped with an additional Main Pump
(Pressure) Filter and a filter indicator box that gives the
operator a visual status of the condition of the filters. The
green light indicates no service required and the red light
means service is required.
The suction strainer has no indicating device and must be
visually inspected.
Summary of Contents for Super Claws LS-2
Page 2: ......
Page 16: ...GENERAL Super Claws Model LS 2 Section 2 4 MAR 2006 4945 3500 Page Intentionally Left Blank ...
Page 76: ......