PAMS
Technical Documentation
NSE–5
Service Software Instructions
Page 38
Issue 1 07/99
If both of these (RSSI reading and the frequency) seem to be correct and
calibration still fails the most probable reason is that there is a little lack of
gain somewhere or the AGC gain control slope in N600 is out of the limits.
This can be verified by changing the generator reference levels from the
demanded ones in the calibration procedure in 1–dB steps up and down.
If the calibration goes through with some reference levels the corrective
action is most probably changing N500 or N600.
Dialog mode: modal
RX Calibration dialog has the following items:
AFC information box:
Shows AGC,DAC voltage.
AGC List box (ALT+A):
AGC, DAC, Voltage and Difference. The difference column shows the
difference between tuned DAC values and mean straight line calculated
from part slopes in dBs (see /1/). This can be calculated when all mea-
surement results have been received from phone.
Repeat button (ALT+R):
The measurement can be started again by pressing this button.
Save button (ALT+S):
Dialog is closed and tuning
is saved to phone.
Cancel button (ESC):
Dialog is closed and tuning
is not saved to phone.
When calibration is ended, the DAC value checking is made and if it is not
succeeded, error message is shown.
When exit is made, the next selections are set to the values which were
selected before this adjustment.
Operation Mode
Update RF Information window
The exit and the use of AGC–control values is done same way as exit
from power level tuning and power coefficient use.
Summary of Contents for NSE-5 Series
Page 15: ...NSE 5 Series Transceivers PAMS Technical Documentation Issue 1 07 99 Chapter 2 System Module...
Page 97: ...PAMS Technical Documentation Issue 1 07 99 Mechanical Assembly...
Page 195: ...NSE 5 Series Transceivers PAMS Technical Documentation Issue 1 07 99 Service Tools...
Page 219: ...PAMS Technical Documentation NSE 5 Series Transceivers Issue 1 07 99 Disassembly Instructions...
Page 227: ...NSE 5 Series Transceivers PAMS Technical Documentation Issue 1 07 99 Troubleshooting...
Page 267: ...PAMS Technical Documentation Original 11 97 HFU 2 Handsfree Unit...
Page 316: ...NSE 5 Schematics Layouts V13 A 2 Page Draft 05 RF and BB Interconnections...
Page 317: ...NSE 5 Schematics Layouts V13 A 3 Page Draft 05 Baseband Block...
Page 318: ...NSE 5 Schematics Layouts V13 A 4 Page Draft 05 Audio...
Page 319: ...NSE 5 Schematics Layouts V13 A 5 Page Draft 05 CPU...
Page 320: ...NSE 5 Schematics Layouts V13 A 6 Page Draft 05 Infrared Module...
Page 321: ...NSE 5 Schematics Layouts V13 A 7 Page Draft 05 Power...
Page 323: ...NSE 5 Schematics Layouts V13 A 9 Page Draft 05 CRFU3...
Page 324: ...NSE 5 Schematics Layouts V13 A 10 Page Draft 05 PA...
Page 325: ...NSE 5 Schematics Layouts V13 A 11 Page Draft 05 SUMMA...
Page 326: ...NSE 5 Schematics Layouts V13 A 12 Page Draft 05 Component Layout Top...
Page 327: ...NSE 5 Schematics Layouts V13 A 13 Page Draft 05 Component Layout Bottom...