WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Hood Open When
Charging.
1. Transport machine to a well ventilated area for
charging.
2. Lead acid batteries: Before charging the batteries,
check the electrolyte level in each battery cell
(Figure 16).
FIG. 16
FOR SAFETY: When servicing machine, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
The electrolyte level (A) should slightly cover the
battery plates (B). Add distilled water as needed.
DO NOT OVERFILL, the fluid may expand and
overflow while charging. Replace cell caps before
charging (Figure 17).
A
B
FIG. 17
3. Connect the charger’s AC power supply cord to a
properly grounded receptacle (Figure 18).
Grounded
3 Hole Outlet
Ground Pin
(120V)
FIG. 18
5. Plug charger’s DC output connector to battery
connector located near battery compartment. Rest
the recovery tank on the support stand to promote
ventilation during charging (Figure 19).
FIG. 19
FOR SAFETY: Do not operate charger unless cord
is properly grounded.
6. The charger will automatically begin charging and
shut off when fully charged.
NOTE:
The machine will not operate once the battery
charger is connected.
ATTENTION: Do not disconnect the charger’s DC
cord from the machine’s receptacle when the
charger is operating. Arcing may result. If the
charger must be interrupted during charging,
disconnect the AC power supply cord first.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.