OPERATION
Falcon
t
Ultra B (07--05)
8
6. After batteries are properly installed, turn on the
main switch and check battery meter charge level
to ensure batteries are fully charged. Charge if
necessary, See Battery Charging (Figure 3).
FIG. 3
MACHINE SETUP
FILLING SOLUTION TANK
1. Transport machine to filling station. Raise
brush/pick-up head when transporting.
2. Turn off main switch.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine.
3. Open solution fill door at front of machine and fill
solution tank with 64 L (17 gal) of clean water,
60
°
C (140
°
F) maximum temperature. Or you can
use the rear fill port to fill solution tank. Twist off
plug and insert hose to fill. The clear tube below
the fill port has 19 L (5 gal) increment markers to
indicate amount of water in tank (Figure 4).
FIG. 4
NOTE:
The water must
not
be hotter than 60
_
C
(140
_
F) or tank damage may occur.
NOTE:
When filling the solution tank with a bucket,
make sure that the bucket is clean. Do not use the
same bucket for filling and draining the machine.
WARNING: Fire or Explosion Hazard.
Never Use Flammable Liquids.
4. Add cleaning chemical. See proper dilution ratio
instructions on bottle.
FOR SAFETY: When using machine, follow mixing
and handling instructions on chemical containers.
ATTENTION: Use only recommended detergents.
Machine damage due to improper detergent usage
will void the manufacturer’s warranty. Contact
your Tennant Sales Representative for detergent
recommendations.
ADJUSTING CONTROL GRIP HEIGHT
The machine has three control grip height settings.
1. Locate two spring loaded levers below console.
2. Squeeze levers together and lift or lower control
grips to a comfortable operating height
(Figure 5).
FIG. 5