OPERATION
Falcon
t
Ultra B (05--99)
18
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
No power.
Faulty main switch.
Contact Service Center.
Batteries need charging.
See Charging Batteries.
Main circuit breaker is pulled out.
Depress main circuit breaker.
Faulty battery(s).
Replace battery(s).
Loose battery cable.
Tighten loose cable.
MAIN circuit breaker has tripped.
Determine cause and reset circuit breaker
button.
Brush motor does not
operate.
Pump switch is not on.
Turn on pump switch.
Control grips are not rotated.
Rotate control grips.
Brush circuit breaker has tripped or is
pulled out.
Remove obstruction from brush and reset
brush circuit breaker button.
Faulty brush motor or wiring.
Contact Service Center.
Carbon brushes worn.
Contact Service Center.
Loose or broken belt.
Replace, or contact Service Center.
Vacuum motor does not
operate.
Faulty vacuum switch.
Contact Service Center.
Vacuum motor thermal overload activated.
Remove obstruction and wait 20 minutes
for motor to cool.
Faulty vacuum motor or wiring.
Contact Service Center.
Carbon brushes worn.
Contact Service Center.
Drive motor does not
operate.
Drive motor circuit breaker has tripped.
Determine cause and reset breaker.
Faulty speed control board or connection.
Contact Service Center.
Faulty solenoid.
Contact Service Center.
Faulty drive motor.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Worn carbon brushes.
Contact Service Center.
Drive motor operates, but
not correctly.
Faulty potentiometer or speed control
board.
Contact Service Center.
Loose wire connection.
Contact Service Center.
Uneven or no solution spray. Twist--out spray tips are plugged.
Remove and clean.
Control grips are not rotated.
Rotate control grips.
Solution line or solution tank filter is
clogged.
Remove hose and blow compressed air
through it. Flush solution tank after each
use.
Inline strainer filter is plugged.
Drain solution tank, remove filter and
clean. Located under machine at rear.
Faulty pump switch.
Contact Service Center.
Faulty pump or solenoid.
Contact Service Center.
Short run time.
Batteries not fully charged.
Charge batteries.
Bad cell in one or more batteries.
Replace battery.
Batteries need maintenance.
See Battery Maintenance.
Faulty charger.
Replace battery charger.