TROUBLE SHOOTING --Continued
PROBLEM
CAUSE
SOLUTION
Poor vacuum recovery.
Recovery tank is full.
Empty recovery tank.
Float shut-off screen inside recovery tank
is clogged.
Remove screen and clean.
Pick-up head is clogged with debris.
Remove debris, use coat hanger.
Pick-up head is not sealed to carpet.
Adjust pick-up head.
Faulty actuator.
Contact Service Center.
Vacuum hose connections are loose or
hose has a hole.
Push hose cuffs firmly on connections.
Replace hose if damaged.
Vacuum hose is clogged with debris.
Remove clogged debris.
Recovery tank inlet hole is obstructed.
Empty recovery tank and tilt tank sideways
to access inlet hole, remove obstruction.
Tank gasket is defective.
Replace gasket.
Drain hose plug is loose.
Tighten drain plug.
Recovery tank lid is loose.
Tighten lid.
Vacuum motor is loose.
Contact Service Center.
Battery charge level is low.
Charge batteries. Do not run machine
when battery meter is in the red zone.