1.6 LEGAL WARRANTY

To  benefit  from  legal  warranty,  the  user  must 

 

strictly comply with the provisions indicated in this 

manual. In particular, the user will have to:

• always work within the use limitations of the product;

• always carry out routine maintenance;

•  authorize  the  use  of  the  machine  only  to  people 

with proven capacity, attitudes and who are ade-

quately trained for the purpose;

• use original spare parts specifically intended for 

the appliance model in use.

It is also necessary to provide the following:

• fiscal receipt reporting date of purchase;

• a certificate of compliance for the installation of the 

product, issued by authorized staff.

Non-compliance with the provisions contained in this 

manual will imply immediate forfeiture of the 

 

warranty for both the product and any spare parts 

assembled thereafter.

1.7 EXCLUSIONS FROM WARRANTY

The warranty excludes all malfunctions and/or 

 

damage to the appliance resulting from the 

 

following causes:

• damage caused by transport and/or handling;

• all parts resulting as being faulty due to   

   negligence or careless use, wrong 

   maintenance, or installation non-conforming 

to the manufacturer instructions 

(please, refer to the installation and use manual  

   supplied with the appliance);

• further damage caused by wrong intervention 

   by the user in the attempt to solve a preexisting fault;

• aggravated damage caused by further use 

   of the appliance by the user once 

   a fault has occurred;

• in the presence of a boiler, any corrosion, 

   scale or breakages caused by stray 

   current, condensate, abrasion or acidity in the 

   water, scale removal treatments carried out 

   improperly, water shortage, sludge or limescale deposits;

• inefficiency of the chimneys, chimney flues or parts of the   

   system on which the appliance depends;

• damage caused by tampering with the appliance, 

   atmospheric agents, natural disasters, vandalism,   

   electrical discharge, fire, faulty electrical and/or 

   plumbing system.

The following are also excluded from the warranty:

• parts subject to normal wear such as gaskets, 

   glass, coverings and cast iron grates, painted, 

   chrome-plated or gold-plated parts, handles and 

   electrical cables, lights, switch resistor, indicator lights,   

   knobs, and all those parts that can be removed from 

   the fireplace (e.g. refractory, brazier);

• color variations of painted and ceramic parts, 

   as well as ceramic cracks (being natural features 

   of the material and consequent to use of the product;

• masonry works;

• parts of the system (if present) not supplied by 

   the manufacturer;

Therefore, any technical interventions on the product 

for the elimination of the aforementioned defects 

and consequent damages must be agreed with the 

Technical Assistance Center, which reserves the right 

to accept or refuse the relevant assignment and in 

any case will not carry out the task as a guarantee, 

but as technical assistance to be provided under 

the conditions possibly and specifically agreed and 

according to the rates in force for the work to be 

carried out. The user will also be charged for the 

costs that may become necessary to remedy his/

her incorrect technical interventions, tampering or, in 

any case, factors which can be harmful to the  

device and that cannot be attributed to  

manufacturing defects. Without prejudice to the 

limits imposed by laws or regulations, any warranty of 

containment of air and noise pollution is also excluded.

• The product can be used by children over   

   8 years of age and people with reduced 

   physical, sensor or mental capacity, or without 

   experience or the necessary know-how, provided   

   that they are supervised, or have received 

   instructions on the safe use of the appliance and are  

  aware of the dangers an improper use may involve.     

  Children must not play with the appliance.

• Cleaning and maintenance intended to be 

   carried out by the user must not be carried out 

   by children without supervision.

• Do not dry the laundry on the the product. 

• The fuel and other flammable materials must

   be kept at a suitable distance from the product.  

   Fire hazard.

• The product must be electrically connected 

   to a system equipped with a suitable grounding  

   system.

• In the event of a fault in the switch-on system, do not 

   force ignition using flammable material. Consult an   

   authorized technician.

• For non-hermetic products, installation in small rooms  

   and bedrooms is forbidden.

• Installation is forbidden in environments with an 

   explosive atmosphere. 

Summary of Contents for H17 V LIGHT

Page 1: ...EN Installation use and maintenance manual H17 V LIGHT...

Page 2: ...oduct Please keep the manual in a suitable place after consulting it carefully Improper installation incorrect maintenance and or misuse of the product relieve the manufacturer of any liability toward...

Page 3: ...oading 20 8 Description of remote control commands 21 8 1 Description of receiver 21 8 2 Description of remote control keys 21 8 3 Description of remote control display 22 8 4 Flat battery signalling...

Page 4: ...regular basis do not remove or bypass this devices 1 3 IMPROPER USE The product is intended to be used for the purpos es and within the limits for which it was expressly de signed for any other use th...

Page 5: ...nted chrome plated or gold plated parts handles and electrical cables lights switch resistor indicator lights knobs and all those parts that can be removed from the fireplace e g refractory brazier co...

Page 6: ...able and reduce the overall efficiency of the system are created Hermetic products can also be installed in the presence of forced ventilation or in premises which can go into negative pressure if com...

Page 7: ...ide not from other rooms garage etc and must have a net useful section equal or higher than 80 cm2 for pellet stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not ne...

Page 8: ...in the country of installation e g in Italy only roof discharge is permitted UNI 10683 standard states that the stack must meet the following characteristics the smoke outlet section must be at least...

Page 9: ...lue with perforation for the passage of the piping increased of minimum 100mm around the pipe if in contact with inflammable parts such as cement bricks etc minimum 300mm around the pipe or as describ...

Page 10: ...et cting it to the chimney flue By using the 4 adjustment feet find the right level so that the smoke discharge and the pipe are connected correctly Once the installation has been carried out the tech...

Page 11: ...7 The door can be ope ned and closed to allow access to the emergency console 3 9 RIGHT FRONT PANEL ASSEMBLY fig 2 Take the left panel from the packaging and take it to vertical position to fix the 2...

Page 12: ...hydraulic system of the product to the house system Product connection to the the house hydraulic system must be carried out exclusively by specialized personnel able to perform the installation to pe...

Page 13: ...se before installing the appliance is para mount EXPANSION VESSEL In case of overheatinghe product is equipped with an expansion vessel to compensate for the increa se in water pressure inside the boi...

Page 14: ...ermosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 8 4 EXAMPLES OF HYDRAULIC DIAGRAMS DIAGRAM 0...

Page 15: ...a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 5 6 7 2 9 11 12 12 13 14 10 8 15 16 17 18 DIAGRAM 01 D...

Page 16: ...ola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 6 7 2 9 11 12 12 13 14 10 8 18 10 19 DIAGRAM 02 TEC...

Page 17: ...to a parete Riscaldamento a pavimento Riscaldamento a termosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 6 7 8 15 16 17 D...

Page 18: ...precautions all parts of the product must be cold ensure there is no form of combustion whatsoever for example hot ash use safety devices as per directive remove the plug from the electrical socket o...

Page 19: ...radio device complies with Directive 2014 53 EU Full text of the EU declaration of conformity is available at the following Internet address https www nobisfire it wp content uploads 2019 04 DoC Palma...

Page 20: ...F EXT THERMOSTAT TERMINAL EXTERNAL THERMOSTAT Fuel is loaded by opening the door and inserting pellets from the upper part of the product Please make sure that pellets contained in the bag do not fall...

Page 21: ...pairing button 10 Manual upgrade button use by authorized staff ONLY Before connection using the emergency cable remove the batteries from the remote control FIRE HAZARD 1 3 2 4 5 6 7 8 9 10 1 2 3 4...

Page 22: ...roll keys POWER it shows the appliance power which can be MINIMUM minimum editable power MAXIMUM maximum editable power see specific section ECO product modulation when setting values are reached SANI...

Page 23: ...mptying ACTIVE COMFORT CLIMA RESTART FROM COMFORT CLIMA FINAL CLEANING OFF ALERT see specific paragraph FLAME OVERHEATING PELLET OVERLOAD 8 5 ICONS OVERVIEW 1 2 4 3 MEANING H2 O STANDBY FAULTY PRESSUR...

Page 24: ...ATING PROCEDURE MENU USER SETTINGS PROBE ADJUSTMENTS Access user menu by pressing Scroll down entries to select SETTINGS using Access the menu by pressing OK OK By pressing scroll down entries to sele...

Page 25: ...eration will be followed by acoustic signal and any alarms will be reset For models equipped with an automatic cleaner during the switch on phase the product activates a brazier cleaning phase before...

Page 26: ...he temperature needed for the appliance to restart STATUS SCREEN To display the appliance shutdown on the display while in COMFORT CLIMA mode screen must be displayed To see that the appliance is abou...

Page 27: ...hermostated so as to turn it off once the temperature in the room where the product is in stalled has been reached by means of the remote control and using only an external thermostat for the device e...

Page 28: ...e is in the OFF or FINAL CLEANING status before activating this function The number expressed in seconds indicates the ro tation time of the auger during the loading phase After this time is up the au...

Page 29: ...irm by pressing the key and move on to edit extraction OK To edit the extraction setting use keys The values vary from 5 reduction in extraction to 5 increase in extraction in Confirm by pressing and...

Page 30: ...ce of a DHW storage tank with SUMMER settings OPERATING PROCEDURE MENU USER SETTINGS SEASON Access the menu by pressing Scroll down entries to select USER using Access the menu by pressing Scroll down...

Page 31: ...STAND BY screen press repeatedly 12 10 ANTICONDENSATION exhaust fumes temperature This function ensures that the exhaust fumes temperature remains higher than condensate temperature OPERATING PROCEDUR...

Page 32: ...ged by the appliance thanks to a contact or immersion probe not provided to be connected on the back side of the product The new stand by screen is shown below To return to the STAND BY screen press r...

Page 33: ...heating by means of a con tact or immersion probe not provided always to be connected on the back of the product The new stand by screen is shown below STAND BY SCREEN 1 2 2 It shows the technical wa...

Page 34: ...TING FOR FLAME FLAME PHASE RESTART PHASE DESCRIPTION Room temperature set on MAN mode In this case the appliance will operate only when the power of the combustion chamber has been set it NEVER switch...

Page 35: ...t an authorized technician to solve the problem Anomaly to the upstream probe mo nitoring the water temperature in the technical water storage tank hot water tank please contact an authorized technici...

Page 36: ...OWER SUPPLY No power supply or power supplied by the electronic control unit is inadequate SOLUTION If the problem persists contact the Support Service ALARM CODE REASON 11 MINIMUM PRESSURE PASCAL The...

Page 37: ...M CODE REASON 29 CLEANING CYCLE LIMIT Maximum limit of cleaning cycles allowed during a prolonged working phase has been reached SOLUTION Vacuum the brazier in full safety and switch the product on ag...

Page 38: ...way as to ensure easy access to the appliance itself and to the flue for cleaning and maintenance operations Lift the lever supplied with the product to unlock and open the door as illustrated in the...

Page 39: ...asive effect avoiding the use of products with additives which could over time wear out seals glass and paint Do not switch on the appliance if the glass is damaged Contact the support service to repl...

Page 40: ...ce intervention for proper operation are summarised below PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD...

Page 41: ...UAL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH FRONT VENTILATION PC CONNECTION technical support only USB CONNECTION technic...

Page 42: ...Use and Maintenance Manual model H17 V LIGHT 42 ENGLISH DATE NOTE...

Page 43: ...Use and Maintenance Manual model H17 V LIGHT 43 ENGLISH DATE NOTE...

Page 44: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0025N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...