background image

Use and Maintenance Manual model “H17 V LIGHT”

    

ENGLISH

1

INTRODUCTION

Nobis products

 are designed and manufactured 

in compliance with the reference standards for 

manufacturing products (EN13240 wood stoves, 

EN14785 pellet appliances, EN13229 fireplaces/

wood-burning inserts, EN12815 wood-burning cookers), 

with high quality materials. The products also comply 

with the essential requirements of Directive 2006/95/EC

(Low Voltage) and Directive 2004/108/EC 

(Electromagnetic Compatibility).

Any printing, translation and reproduction,

even partial, of this manual are intended

bound to the manufacturer’s authorization, and the

content of operating logics and explanatory figures 

is considered not to be disclosed.

Always consult authorized technicians in case of

any doubts about the functioning of the product.

The manufacturer reserves the right to make changes to 

specifications and technical and/or working features of 

the product at any time and without prior warning.

1.1 SYMBOLS

This manual contains symbols highlighting 

the importance of particular descriptions 

or concepts;

INFORMATION: complying with the product’s 

specifications guarantees its correct operation.

WARNING: this symbol is used to identify 

information of particular importance.

DANGER: the presence of this symbol indicates 

that utmost attention is required to guarantee 

both user and product safety.

1.2 INTENDED USE

This is a manual for a fireplace for domestic heating, 

fed by automatic loading and using wood pellets only.

This product has been designed and manufactured 

to work in safety if the following conditions occur:

• 

installation by specialized staff in compliance with the 

   specific reference standards;

• use within the limits declared on the product 

   data sheet and in this manual;

• compliance with technical procedures as described 

   in the manual;

• carrying out routine maintenance according to times   

   and methods indicated in this manual;

• prompt execution of extraordinary maintenance 

   if necessary (e.g. in case of malfunctioning);

• the safety devices are working properly and 

   maintained on a regular basis (do not remove or 

   bypass this devices).

1.3 IMPROPER USE

The product is intended to be used for the purpos-

es and within the limits for which it was expressly de-

signed; for any other use, the manufacturer cannot 

be held in any way liable for damage caused to 

people, animals or property. 

Improper use is meant as:

• using the product as an incinerator;

• use of the product with fuel other thanØ 6mm wood   

   pellets;

• Fuelling the product with liquid fuel;

• using the product with the fire door open and/or 

   broken glass and/or ash pan removed and/or 

   pellet tank open.

Any other use of the appliance other than that for 

which it has been intended must be authorized in ad-

vance in writing by the manufacturer.

Furthermore, the manufacturer cannot be held in 

any way liable for any mistakes in the installation,  

adjustment or maintenance of the product.

1.4 IMPORTANCE OF THE MANUAL

This manual has the purpose of providing essential 

rules for proper installation, use and maintenance of 

the product.

STORAGE: please, store the manual in a place that is 

easy and quick to find;

DETERIORATION OR LOSS: please, consult our official 

website to download the manual;

PRODUCT TRANSFER: In the event of sale of the product 

between private individuals, the owner is obliged to  

deliver the product with a copy of this manual included.  

1.5 GENERAL SAFETY WARNINGS

Non-compliance with the provisions of this manual can 

cause damage to people, animals and property.

• Installation, testing of the system, functionality     

   testing and initial calibration of the product must be  

   carried out by qualified and authorized staff only.

• The product must be connected to a single chimney 

   flue guaranteeing the draught declared by the     

   manufacturer and complying with the installation 

   standards outlined in the place of assembly of the  

   product.

• The premises where the product is installed must be 

   adequately ventilated (air intake).

• Do not touch the hot surfaces without adequate   

   protective equipment, so as to avoid burns.

• When in operation, the external surfaces of the product 

   reach high temperatures.

• It is forbidden to make any changes to the product 

 unless expressly communicated in writing by the  

   manufacturer.

•  In  the  event  of  fire  in  the  chimney  flue,  please 

 

   contact the fire brigade immediately.

Summary of Contents for H17 V LIGHT

Page 1: ...EN Installation use and maintenance manual H17 V LIGHT...

Page 2: ...oduct Please keep the manual in a suitable place after consulting it carefully Improper installation incorrect maintenance and or misuse of the product relieve the manufacturer of any liability toward...

Page 3: ...oading 20 8 Description of remote control commands 21 8 1 Description of receiver 21 8 2 Description of remote control keys 21 8 3 Description of remote control display 22 8 4 Flat battery signalling...

Page 4: ...regular basis do not remove or bypass this devices 1 3 IMPROPER USE The product is intended to be used for the purpos es and within the limits for which it was expressly de signed for any other use th...

Page 5: ...nted chrome plated or gold plated parts handles and electrical cables lights switch resistor indicator lights knobs and all those parts that can be removed from the fireplace e g refractory brazier co...

Page 6: ...able and reduce the overall efficiency of the system are created Hermetic products can also be installed in the presence of forced ventilation or in premises which can go into negative pressure if com...

Page 7: ...ide not from other rooms garage etc and must have a net useful section equal or higher than 80 cm2 for pellet stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not ne...

Page 8: ...in the country of installation e g in Italy only roof discharge is permitted UNI 10683 standard states that the stack must meet the following characteristics the smoke outlet section must be at least...

Page 9: ...lue with perforation for the passage of the piping increased of minimum 100mm around the pipe if in contact with inflammable parts such as cement bricks etc minimum 300mm around the pipe or as describ...

Page 10: ...et cting it to the chimney flue By using the 4 adjustment feet find the right level so that the smoke discharge and the pipe are connected correctly Once the installation has been carried out the tech...

Page 11: ...7 The door can be ope ned and closed to allow access to the emergency console 3 9 RIGHT FRONT PANEL ASSEMBLY fig 2 Take the left panel from the packaging and take it to vertical position to fix the 2...

Page 12: ...hydraulic system of the product to the house system Product connection to the the house hydraulic system must be carried out exclusively by specialized personnel able to perform the installation to pe...

Page 13: ...se before installing the appliance is para mount EXPANSION VESSEL In case of overheatinghe product is equipped with an expansion vessel to compensate for the increa se in water pressure inside the boi...

Page 14: ...ermosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 8 4 EXAMPLES OF HYDRAULIC DIAGRAMS DIAGRAM 0...

Page 15: ...a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 5 6 7 2 9 11 12 12 13 14 10 8 15 16 17 18 DIAGRAM 01 D...

Page 16: ...ola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 6 7 2 9 11 12 12 13 14 10 8 18 10 19 DIAGRAM 02 TEC...

Page 17: ...to a parete Riscaldamento a pavimento Riscaldamento a termosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 6 7 8 15 16 17 D...

Page 18: ...precautions all parts of the product must be cold ensure there is no form of combustion whatsoever for example hot ash use safety devices as per directive remove the plug from the electrical socket o...

Page 19: ...radio device complies with Directive 2014 53 EU Full text of the EU declaration of conformity is available at the following Internet address https www nobisfire it wp content uploads 2019 04 DoC Palma...

Page 20: ...F EXT THERMOSTAT TERMINAL EXTERNAL THERMOSTAT Fuel is loaded by opening the door and inserting pellets from the upper part of the product Please make sure that pellets contained in the bag do not fall...

Page 21: ...pairing button 10 Manual upgrade button use by authorized staff ONLY Before connection using the emergency cable remove the batteries from the remote control FIRE HAZARD 1 3 2 4 5 6 7 8 9 10 1 2 3 4...

Page 22: ...roll keys POWER it shows the appliance power which can be MINIMUM minimum editable power MAXIMUM maximum editable power see specific section ECO product modulation when setting values are reached SANI...

Page 23: ...mptying ACTIVE COMFORT CLIMA RESTART FROM COMFORT CLIMA FINAL CLEANING OFF ALERT see specific paragraph FLAME OVERHEATING PELLET OVERLOAD 8 5 ICONS OVERVIEW 1 2 4 3 MEANING H2 O STANDBY FAULTY PRESSUR...

Page 24: ...ATING PROCEDURE MENU USER SETTINGS PROBE ADJUSTMENTS Access user menu by pressing Scroll down entries to select SETTINGS using Access the menu by pressing OK OK By pressing scroll down entries to sele...

Page 25: ...eration will be followed by acoustic signal and any alarms will be reset For models equipped with an automatic cleaner during the switch on phase the product activates a brazier cleaning phase before...

Page 26: ...he temperature needed for the appliance to restart STATUS SCREEN To display the appliance shutdown on the display while in COMFORT CLIMA mode screen must be displayed To see that the appliance is abou...

Page 27: ...hermostated so as to turn it off once the temperature in the room where the product is in stalled has been reached by means of the remote control and using only an external thermostat for the device e...

Page 28: ...e is in the OFF or FINAL CLEANING status before activating this function The number expressed in seconds indicates the ro tation time of the auger during the loading phase After this time is up the au...

Page 29: ...irm by pressing the key and move on to edit extraction OK To edit the extraction setting use keys The values vary from 5 reduction in extraction to 5 increase in extraction in Confirm by pressing and...

Page 30: ...ce of a DHW storage tank with SUMMER settings OPERATING PROCEDURE MENU USER SETTINGS SEASON Access the menu by pressing Scroll down entries to select USER using Access the menu by pressing Scroll down...

Page 31: ...STAND BY screen press repeatedly 12 10 ANTICONDENSATION exhaust fumes temperature This function ensures that the exhaust fumes temperature remains higher than condensate temperature OPERATING PROCEDUR...

Page 32: ...ged by the appliance thanks to a contact or immersion probe not provided to be connected on the back side of the product The new stand by screen is shown below To return to the STAND BY screen press r...

Page 33: ...heating by means of a con tact or immersion probe not provided always to be connected on the back of the product The new stand by screen is shown below STAND BY SCREEN 1 2 2 It shows the technical wa...

Page 34: ...TING FOR FLAME FLAME PHASE RESTART PHASE DESCRIPTION Room temperature set on MAN mode In this case the appliance will operate only when the power of the combustion chamber has been set it NEVER switch...

Page 35: ...t an authorized technician to solve the problem Anomaly to the upstream probe mo nitoring the water temperature in the technical water storage tank hot water tank please contact an authorized technici...

Page 36: ...OWER SUPPLY No power supply or power supplied by the electronic control unit is inadequate SOLUTION If the problem persists contact the Support Service ALARM CODE REASON 11 MINIMUM PRESSURE PASCAL The...

Page 37: ...M CODE REASON 29 CLEANING CYCLE LIMIT Maximum limit of cleaning cycles allowed during a prolonged working phase has been reached SOLUTION Vacuum the brazier in full safety and switch the product on ag...

Page 38: ...way as to ensure easy access to the appliance itself and to the flue for cleaning and maintenance operations Lift the lever supplied with the product to unlock and open the door as illustrated in the...

Page 39: ...asive effect avoiding the use of products with additives which could over time wear out seals glass and paint Do not switch on the appliance if the glass is damaged Contact the support service to repl...

Page 40: ...ce intervention for proper operation are summarised below PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD...

Page 41: ...UAL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH FRONT VENTILATION PC CONNECTION technical support only USB CONNECTION technic...

Page 42: ...Use and Maintenance Manual model H17 V LIGHT 42 ENGLISH DATE NOTE...

Page 43: ...Use and Maintenance Manual model H17 V LIGHT 43 ENGLISH DATE NOTE...

Page 44: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0025N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Reviews: