1

2

12.2 AUGER LOADING FUNCTION

OK

OK

12.3 PELLET/AIR-INTAKE RATIO

OPERATING PROCEDURE:

 

MENU >> USER>> AUGER LOADING

Access the menu by pressing key
Scroll the entries to USER with the key  

OK

To edit the switch on/off times, as well as enabling 

the days of the week, press keys  

Confirm each data change using the key       and 

move on to the second screen of the TIMER program. 

The screen in the figure below shows the settings 

options for both desired room temperature and 

maximum boiler-water temperature during the 

activation of the time frame       . It is also possible to 

control the ventilation speed (if applicable)       . 

OK

1

2

Edit the values using the keys  

Confirm each data change using the 

key      until you exit the program.

OK

While editing, remember the following:

• press        to return to the previous data, without 

saving the last data changed; 

• 

if you intend to change one single datum, once the 

change has been made, press       multiple times until 

you exit the function.
To return to the STAND-BY screen, press           repeatedly.

OK

This function is necessary to facilitate the switch on 

phase of the appliance, after accurate cleaning of 

the hopper (pellet container) to remove sawdust - 

which accumulates on its base over time - has been 

carried out. See the chapter “Routine maintenance 

of the product” for further info.

Also, make sure that pellets have been properly load-

ed in the tank and that the appliance is in the “OFF” 

or “FINAL CLEANING” status before activating this 

function.

The number - expressed in seconds - indicates the ro-

tation  time of the auger during the loading phase. 

After this time is up, the auger stops automatically, 

and the appliance can switch on.

Access the menu by pressing
Scroll the entries to AUGER LOADING and press  
Access the function by pressing key    
The cleaner activates (for models equipped with 

automatic cleaning) and then pellet loading is 

enabled. The display will show a countdown: as it 

reaches “0“, the loading will stop.

OK

At the end of the loading phase, the appliance will 

show the USER screen.

The PELLET/AIR-INTAKE RATIO settings allow you to 

change, with immediate effect, the quantity of pel-

lets loaded in the brazier and the quantity of air in-

bound of the product, tested and inspected with DIN 

PLUS certified pellets. If you use other pellets or uncer

-

tified pellets, combustion may need to be adjusted. 

Normally, the change is performed on the EXTRAC-

TION percentage to improve combustion; if oxygen 

adjustment  is  not  efficient,  you  may  need  to  also 

change the percentage of PELLETS falling.

OPERATING PROCEDURE:

 MENU >> USER>> P/A RATIO

Access the menu by pressing key
Scroll the entries to USER, key  
Access the menu by pressing key
Scroll the entries to P/A RATIO with the key  
Access the function by pressing key    

OK

OK

OK

OK

After the initial loading phase, a POPUP will appe-

ar, indicating the sucking of pellets from the brazier. 

This operation does not allow emptying the pellets 

into the ash drawer when the plate is rotating during 

ignition.
Always vacuum the brazier using an ash cleaner. 

FIRE HAZARD.

Summary of Contents for H17 V LIGHT

Page 1: ...EN Installation use and maintenance manual H17 V LIGHT...

Page 2: ...oduct Please keep the manual in a suitable place after consulting it carefully Improper installation incorrect maintenance and or misuse of the product relieve the manufacturer of any liability toward...

Page 3: ...oading 20 8 Description of remote control commands 21 8 1 Description of receiver 21 8 2 Description of remote control keys 21 8 3 Description of remote control display 22 8 4 Flat battery signalling...

Page 4: ...regular basis do not remove or bypass this devices 1 3 IMPROPER USE The product is intended to be used for the purpos es and within the limits for which it was expressly de signed for any other use th...

Page 5: ...nted chrome plated or gold plated parts handles and electrical cables lights switch resistor indicator lights knobs and all those parts that can be removed from the fireplace e g refractory brazier co...

Page 6: ...able and reduce the overall efficiency of the system are created Hermetic products can also be installed in the presence of forced ventilation or in premises which can go into negative pressure if com...

Page 7: ...ide not from other rooms garage etc and must have a net useful section equal or higher than 80 cm2 for pellet stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not ne...

Page 8: ...in the country of installation e g in Italy only roof discharge is permitted UNI 10683 standard states that the stack must meet the following characteristics the smoke outlet section must be at least...

Page 9: ...lue with perforation for the passage of the piping increased of minimum 100mm around the pipe if in contact with inflammable parts such as cement bricks etc minimum 300mm around the pipe or as describ...

Page 10: ...et cting it to the chimney flue By using the 4 adjustment feet find the right level so that the smoke discharge and the pipe are connected correctly Once the installation has been carried out the tech...

Page 11: ...7 The door can be ope ned and closed to allow access to the emergency console 3 9 RIGHT FRONT PANEL ASSEMBLY fig 2 Take the left panel from the packaging and take it to vertical position to fix the 2...

Page 12: ...hydraulic system of the product to the house system Product connection to the the house hydraulic system must be carried out exclusively by specialized personnel able to perform the installation to pe...

Page 13: ...se before installing the appliance is para mount EXPANSION VESSEL In case of overheatinghe product is equipped with an expansion vessel to compensate for the increa se in water pressure inside the boi...

Page 14: ...ermosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 8 4 EXAMPLES OF HYDRAULIC DIAGRAMS DIAGRAM 0...

Page 15: ...a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 5 6 7 2 9 11 12 12 13 14 10 8 15 16 17 18 DIAGRAM 01 D...

Page 16: ...ola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 6 7 2 9 11 12 12 13 14 10 8 18 10 19 DIAGRAM 02 TEC...

Page 17: ...to a parete Riscaldamento a pavimento Riscaldamento a termosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 6 7 8 15 16 17 D...

Page 18: ...precautions all parts of the product must be cold ensure there is no form of combustion whatsoever for example hot ash use safety devices as per directive remove the plug from the electrical socket o...

Page 19: ...radio device complies with Directive 2014 53 EU Full text of the EU declaration of conformity is available at the following Internet address https www nobisfire it wp content uploads 2019 04 DoC Palma...

Page 20: ...F EXT THERMOSTAT TERMINAL EXTERNAL THERMOSTAT Fuel is loaded by opening the door and inserting pellets from the upper part of the product Please make sure that pellets contained in the bag do not fall...

Page 21: ...pairing button 10 Manual upgrade button use by authorized staff ONLY Before connection using the emergency cable remove the batteries from the remote control FIRE HAZARD 1 3 2 4 5 6 7 8 9 10 1 2 3 4...

Page 22: ...roll keys POWER it shows the appliance power which can be MINIMUM minimum editable power MAXIMUM maximum editable power see specific section ECO product modulation when setting values are reached SANI...

Page 23: ...mptying ACTIVE COMFORT CLIMA RESTART FROM COMFORT CLIMA FINAL CLEANING OFF ALERT see specific paragraph FLAME OVERHEATING PELLET OVERLOAD 8 5 ICONS OVERVIEW 1 2 4 3 MEANING H2 O STANDBY FAULTY PRESSUR...

Page 24: ...ATING PROCEDURE MENU USER SETTINGS PROBE ADJUSTMENTS Access user menu by pressing Scroll down entries to select SETTINGS using Access the menu by pressing OK OK By pressing scroll down entries to sele...

Page 25: ...eration will be followed by acoustic signal and any alarms will be reset For models equipped with an automatic cleaner during the switch on phase the product activates a brazier cleaning phase before...

Page 26: ...he temperature needed for the appliance to restart STATUS SCREEN To display the appliance shutdown on the display while in COMFORT CLIMA mode screen must be displayed To see that the appliance is abou...

Page 27: ...hermostated so as to turn it off once the temperature in the room where the product is in stalled has been reached by means of the remote control and using only an external thermostat for the device e...

Page 28: ...e is in the OFF or FINAL CLEANING status before activating this function The number expressed in seconds indicates the ro tation time of the auger during the loading phase After this time is up the au...

Page 29: ...irm by pressing the key and move on to edit extraction OK To edit the extraction setting use keys The values vary from 5 reduction in extraction to 5 increase in extraction in Confirm by pressing and...

Page 30: ...ce of a DHW storage tank with SUMMER settings OPERATING PROCEDURE MENU USER SETTINGS SEASON Access the menu by pressing Scroll down entries to select USER using Access the menu by pressing Scroll down...

Page 31: ...STAND BY screen press repeatedly 12 10 ANTICONDENSATION exhaust fumes temperature This function ensures that the exhaust fumes temperature remains higher than condensate temperature OPERATING PROCEDUR...

Page 32: ...ged by the appliance thanks to a contact or immersion probe not provided to be connected on the back side of the product The new stand by screen is shown below To return to the STAND BY screen press r...

Page 33: ...heating by means of a con tact or immersion probe not provided always to be connected on the back of the product The new stand by screen is shown below STAND BY SCREEN 1 2 2 It shows the technical wa...

Page 34: ...TING FOR FLAME FLAME PHASE RESTART PHASE DESCRIPTION Room temperature set on MAN mode In this case the appliance will operate only when the power of the combustion chamber has been set it NEVER switch...

Page 35: ...t an authorized technician to solve the problem Anomaly to the upstream probe mo nitoring the water temperature in the technical water storage tank hot water tank please contact an authorized technici...

Page 36: ...OWER SUPPLY No power supply or power supplied by the electronic control unit is inadequate SOLUTION If the problem persists contact the Support Service ALARM CODE REASON 11 MINIMUM PRESSURE PASCAL The...

Page 37: ...M CODE REASON 29 CLEANING CYCLE LIMIT Maximum limit of cleaning cycles allowed during a prolonged working phase has been reached SOLUTION Vacuum the brazier in full safety and switch the product on ag...

Page 38: ...way as to ensure easy access to the appliance itself and to the flue for cleaning and maintenance operations Lift the lever supplied with the product to unlock and open the door as illustrated in the...

Page 39: ...asive effect avoiding the use of products with additives which could over time wear out seals glass and paint Do not switch on the appliance if the glass is damaged Contact the support service to repl...

Page 40: ...ce intervention for proper operation are summarised below PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD...

Page 41: ...UAL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH FRONT VENTILATION PC CONNECTION technical support only USB CONNECTION technic...

Page 42: ...Use and Maintenance Manual model H17 V LIGHT 42 ENGLISH DATE NOTE...

Page 43: ...Use and Maintenance Manual model H17 V LIGHT 43 ENGLISH DATE NOTE...

Page 44: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0025N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Reviews: