htk4014a600p_04
21/68
Mounting the probe to the bottom of the tank.
Flexible probes can be fastened with a chuck (ring), turnbuckle or
similar fastening device to the bottom of the tank.
Shortening cable probes
If required, the cable probe can be shortened, but this applies only
when used in liquids.
Process:
1.
Detach socket set screw M6x10 (ISO 4026) with 5 mm (0.20 inch)
Allen (hexagon) key (ISO 2936).
2.
Pull cable out of counterweight and shorten to required length
using cable cutters to prevent the cable wires and strands from
fraying out.
3.
Insert cable back into counterweight and tighten it with screws.
4.
Change configuration parameters with respect to the new probe
length; with the reference point is the top edge of the weight.
4.2.2.
Specific installation instructions: gauge – solid applications
False readings
Conical silo nozzles, false readings and traction on
the cable probes
Do not let the probe touch the side of the nozzle.
High traction forces: We recommend no to
anchor the probe, in order to avoid excessive
traction loads on the cable.
Bending and traction:
Position the connection on the roof at ½ radius of
the tank and with minimum nozzle height. Thus,
the damages might occur during emptying due to
bending or traction can be avoided.