![Nitto Seiko FF503H Instruction Manual Download Page 41](http://html1.mh-extra.com/html/nitto-seiko/ff503h/ff503h_instruction-manual_1696680041.webp)
Vibratory Track Screw Feeder FF/FM503H ver2
31
13) Screw taking-out type/Parts counter type screw feeding solenoid valve ON time setup (Pa.8A)
If the screw taking-out type or parts counter type is used, the screw feeding solenoid valve ON time can
be set up.
(Valid only when the screw taking-out type or parts counter type is used.)
Variable range
From 0.5 to 10.0 sec.
Setup step
0.1 sec.
Default
1 sec.
14) Screw taking-out type/Parts counter type screw feeding solenoid valve OFF time setup (Pa.8B)
If the screw taking-out type or parts counter type is used, the screw feeding solenoid valve OFF time can
be set up.
(Valid only when the screw taking-out type or parts counter type is used.)
Variable range
From 0.5 to 10.0 sec.
Setup step
0.1 sec.
Default
1 sec.
15) Initial running time setup (Pa.8C)
After the power supply is turned on, the compulsion running time of the hopper
and the vibrator can be set up.
Variable range
From 0 to 10.0 sec.
Setup step
1 sec.
Default
5 sec.
16) Parts counter feeding count setup (Pa.A1)
If the parts counter type is used, the number of screws fed per screw feeding signal can be set up.
(Valid only when the parts counter type is used.)
Variable range
1 to 15 screws
Setup step
1 screw
Default
1 screw
8.3.2.
Equipment parameter setup
Setup and adjustment items related to models and options of FF/FM503H are as shown below.
Caution: Normal running operations including screw feed are disabled while the equipment parameter is set
up. (To be more precise, setup items after the parameter Pa.A1 in 2/2 of the function list)
1)
Model setup (Pa.E1)
Model of FF/FM503H can be set up.
Select any of choices from 1 to 5, depending on the type of equipment.
0. Automatic type <default>
1. Hand driver type (micro switch)
2. Hand driver type (reed switch)
3. Screw taking-out type
4. System reserved
5. Parts counter type
As for the correspondence of the indicating status of the LEDs on the panel during the model setup with
the actually selected model, refer to
“8.2.3 FF/FM503H Setup and adjustment mode function list”.
A
ut
o
m
at
ic
ty
p
e
H
an
d
d
ri
ver
t
yp
e
(M
icr
o
s
w
it
ch)
H
and
d
ri
ver
t
yp
e
(R
eed
s
w
it
ch)
S
cr
ew
t
ak
e
o
ut
t
yp
e
P
ar
ts
co
unt
er
t
yp
e