Vibratory Track Screw Feeder FF/FM503H ver2
28
8.3.
Setup and adjustment items
Items shown below can be set up or adjusted from the setup panel.
(1) Operation parameter setup
(A) Basic adjustment mode: Mode for performing the basic vibrator setup (frequency, strength)
Vibrator vibration frequency setup (FREQ.) (Pa.11)
Vibrator vibration strength setup (VIB.) (Pa.21)
Screw feeding time setup (hand driver type) (FEED) (Pa.41)
(B) Fine adjustment mode: Mode for making fine adjustments in order to obtain optimum screw
conditions.
Hopper track operating speed setup (Pa.81)
Screw feeding start waiting time setup (hand driver type: reed switch) (Pa.82)
Setup of waiting time of signal indicating lack of screw occurred on track (Pa.83)
Setup of basket inside lack of screw signal output waiting time (Pa.84) (optional)
Hopper track running start waiting time setup (Pa.85)
Hopper track running stop waiting time setup (Pa.86)
Setup of vibrating time after screw feed (Pa.87)
Hopper track intermittent running ON time setup (Pa.88)
Hopper track intermittent running OFF time setup (Pa.89)
(C) Special mode: Items can be selected when special specifications are selected.
Screw taking-out type/Parts counter type screw feeding solenoid valve ON time setup (Pa.8A)
Screw taking-out type/Parts counter type screw feeding solenoid valve OFF time setup
(Pa.8B)
Initial running time setup(Pa.8C)
Parts counter feeding count setup (Pa.A1)
(2) Equipment parameter setup: Model setup, setup of presence or absence of optional sensor and
continuous running setup can be performed.
Model setup (Pa.E1)
Option setup (Pa.E2)
VIB, HT continuous running setup (Pa.E3)
System reserved(Pa.D1)
The presence of the auxiliry hopper (Pa.D2)
The logic of chute rail work detect sensor (Pa.D3)
The logic of option sensor (Pa.D4)
(3) Special mode setup
The special mode setup comprises the parameter initializing mode, I/O check mode and version check
mode.
8.3.1.
Operation parameter setup
“**” of “Pa.**” in the descriptions means the parameter number. Also refer to
“8.2.3 FF/FM503H Setup
and adjustment mode function list”. Items shown in the tables are as shown below.
Variable range: Range which setup is enabled.
Setup step:
Variation per step
Default:
Value to be set up when parameters are initialized
Caution: For the parameters (Pa.11 to Pa.8B) shown in 1/2 of the function list, an external screw feeding
signal is accepted even during setup and adjustment.