![Nimbra 300 Series Installation And Maintenance Manual Download Page 81](http://html.mh-extra.com/html/nimbra/300-series/300-series_installation-and-maintenance-manual_1694310081.webp)
Installation and Maintenance Manual Nimbra 300 Series
Specifications
•
79
©2006 Net Insight AB, All rights reserved
8 x AES/EBU Audio Transport Module
Module type:
Access module,
NPS0050-3001
Number of ports:
8 x Digital Audio In or Out, individually configurable
1 monitor port
Connectors:
75 Ohm, BNC (female)
Minimum bandwidth:
2 Mbps
Maximum bandwidth:
12 Mbps
LED
State
Description
In (Rx)
Off
disabled
Green
receiving, data OK
Flashing green
DTM loopback mode
Red
loss of video signal
Flashing red
loss of packet alignment
Out (Tx)
Off
disabled
Green
transmitting, data OK
Flashing green
line loopback mode
Red
loss of DTM data
Flashing red
buffer overflow/alarm indication signal
Monitor - In
Off
Rx stream not active
Green
monitor port in Rx stream mode
Monitor - Out
Off
Tx stream not active
Green
monitor port in Tx stream mode