Installation and Maintenance Manual Nimbra 300 Series
Installation
•
41
©2006 Net Insight AB, All rights reserved
Caution:
Class 1 Laser Product.
Complies with 21 CFR 1040.10 and 1040.11
The optical ports must be terminated with an optical connector
or with a dust plug.
The use of optical instruments with this product will increase
eye hazard.
Note:
Avoid bending the optical cables more than the minimum bend
radius of 35 mm. A smaller radius could cause inadequate
signal levels or damage the cables.
Note the cable marking, to avoid swapping input and output
cables.
Handle only one cable at a time. Leave the protecting cap on all
connectors until immediately before connecting the cable.
Clean the cable connector using a standard fiber connector-
cleaning tool.
Connecting Optical Fibers to the SFP Module
Optical fibers are connected to the SFP module according to below.
•
Remove the protective cap from one of the cables and the connector on the SFP
module.
•
Insert the cable carefully in to the connectors of the SFP module and make sure
it is firm and fixed in place.
•
Repeat the procedure for the remaining connections to be made to the SFP
modules of the switch.