Sweep System, Main Broom
219
Service Manual – Advance 7765 / Nilfisk CR1500
Main Broom Sweep System Wiring Diagram
Circuit Description
The
Main Broom Solenoid (2)
valve in the main control valve controls the oil flow to the main broom motor.
The main broom motor will run when the
Ignition Switch
is on and the
Main Broom Switch
on the instrument
panel is switched on.
Note that the
Hopper Switch
and the
Hopper Door Switch
must both be closed for the main broom motor to
operate.
Also refer to the
Main Broom Sweep System Hydraulic Diagrams
section.
Hopper Switch
Hopper Door Switch
(Held Closed by Hopper)
(Held Closed by Door)
15
57
1
Main Broom
Switch
2
Main Broom Solenoid (2)
38
B-
7
7
7
CB6
15 A
13
7
2
C
C
N.O.
N.O.
1
Battery 12 VDC
+
-
Bat.
Ignition
Switch