Sweep System, Main Broom 220
Service Manual – Advance 7765 / Nilfisk CR1500
Main Broom Sweep System Hydraulic Diagrams
Main Broom Motor Off
When the
Main Broom Motor
is off, the
Main Broom Solenoid (2)
is de-energized (open). This allows the
hydraulic oil to flow from the
Auxiliary Pump
through non-priority leg of the priority flow divider, then
through the
Main Broom Solenoid (2)
valve. The oil will then flow to the
Normal Rotation Brush (4)
solenoid
valve, bypassing both the
Main Broom Motor
and the
Dust Control Motor
.
4.50
CIR
.75
GPM
Main
Broom
Motor
1
2
1.02
CIR
1.24 CIR
Return Block
Reservoir
Auxiliary
Pump
Drive
Pump
9.7 GPM
Main Broom
Solenoid (2)
To Normal
Rotation Brush (4)
To Side
Broom
Valve
To Return
Block
To Dust
Control
Motor
From Dust
Control
Motor
Case
Drain
2500
PSI
Main Control
Valve
P
T1