Scrub System
163
Service Manual – Advance 7765 / Nilfisk CR1500
Scrub System Hydraulic Diagrams
Scrub Brush Motors Off
When the
Scrub Brush Motors
are off, the
Normal Rotation Brush (4)
solenoid is de-energized (open). This allows
the hydraulic oil to flow from the
Auxiliary Pump
, through non-priority leg of the priority flow divider and
through the
Normal Rotation Brush (4)
solenoid valve.
•
If the Main Broom Switch is off, the
Main Broom Solenoid (2)
is de-energized (open). The oil will flow
through the
Main Broom Solenoid (2)
valve and
Normal Rotation Brush (4)
solenoid valve, then go to the
Hopper Control Valve
.
To Side
Broom Valve
Scrub Brush
Motors
10.0
CIR
10.0
CIR
0.34
CIR
4.50
CIR
10.0
CIR
.75
GPM
Main Control
Valve
Dust
Control
Motor
Main
Broom
Motor
P
P1
1
2
3
T
4
1.02
CIR
1.24 CIR
Return Block
Reservoir
Drive
and
Auxiliary
Pump
To Hopper
Control Valve
9.7 GPM
T1
Main Broom
Solenoid (2)
Normal Rotation
Brush (4)
Reverse
Rotation
Brush (3)